  • Page 1 Installation instructions and how to use and look after your built-in cooker hoods D99T6N0 NEFF (UK) Ltd...
  • Page 2 Fig. 1 Abb. 1 ELECTRO mind. mind.
  • Page 3: Appliance Description

    Light / fan interlocking, etc. switches If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded.
  • Page 4: Before Using For The First Time

    Use carefully. They contain important you may find descriptions of individual information concerning your personal features that do not apply to your safety as well as on use and care of the specific appliance. appliance. This extractor hood complies with all Please retain the operating and relevant safety regulations.
  • Page 5: Safety Instructions

    Never operate the extractor hood without a grease filter. Overheated fat or oil can easily catch fire. If you are cooking with fat or oil, e.g. chips, etc., never leave the cooker unattended.
  • Page 6: Operating Procedure

    finishing cooking. The fans in this appliance can be switched to the desired setting by hand (manual mode) or can be controlled fully automatically with the automatic function according to your requirements (automatic mode).
  • Page 7 – Intensive setting: 1. To switch on the intensive setting ç press the button. The fan runs for 5 minutes at Setting then switches off for 55 minutes. This process is repeated every hour. Switching off: Press the button. Automatic mode has been switched off.
  • Page 8 Switching on: Press the button. Simultaneously press the buttons. Light The light can be used at any time, even when the appliance has been switched After approx. 3 seconds the light off. switches on to acknowledge the setting. Switching on/off:...
  • Page 9: Filters And Maintenance

    Important: By cleaning the metal grease filters at appropriate intervals, the possibility of them catching fire as a result of a build-up of heat such as occurs when deep-fat frying or roasting is taking place, is reduced. Saturation indicator: When the grease filters reach saturation...
  • Page 10 The activated carbon filter should risk of fire and the function of the extractor be replaced straight away. hood may be impaired. Important: Replacing the activated carbon filter: Change the activated carbon filter promptly...
  • Page 11: Cleaning And Care

    Cleaning and care Isolate the extractor hood by pulling out Stainless steel surfaces: the mains plug or switching off the fuse. Use a mild non-abrasive stainless steel cleaner. Do not clean the extractor hood with Clean the surface in the same direction abrasive sponges or with cleaning agents as it has been ground and polished.
  • Page 12: Replacing The Light Bulbs

    If is not possible to operate the extractor hood: Disconnect the extractor hood from the mains electricity supply by pulling out the plug or switching it off at the main fuse box. Wait for approx. 1 minute and then 3. Replace the halogen light bulb switch it on again.
  • Page 13: Installation Instructions

    Only one side of the extractor hood Please ask your dealer or inquire at your may be installed next to a high-sided unit local authority about current means of or high wall. Gap at least 50 mm.
  • Page 14: Prior To Installation

    flue that is interlocking, etc. currently used for other purposes, nor into a shaft that is used for ventilating rooms in If the air intake is inadequate, there is a which stoves or fireplaces are also located.
  • Page 15 Short, smooth air exhaust pipe. Mount the pipe directly onto the air As few bends in the pipe as possible. outlet on the hood. Diameter of pipe to be as large as possible and no tight bends in pipe.
  • Page 16: Preparing The Wall

    Exhaust air Recirculating air 25,0 26,5 We reserve the right to construction changes within the 1. Press and hold the 0 button. context of technical development. 2. While is displayed, press the ã...
  • Page 17: Electrical Connection

    IMPORTANT: Fitting a Different Plug: regulations. The wires in the mains lead are coloured in If possible, site the earthed socket directly accordance with the following code: behind the chimney panelling.
  • Page 18: Installation

    4. Drill 4 x l 8 mm holes for the extractor hood and 2 x l 8 mm holes for the chimney panelling. Insert plugs into the holes so that they are flush with the wall.
  • Page 19 Installation 08. Screw in the two lower hexagon head 13. Push both sections of the flue panelling cap screws. together (slots in the upper section must be pointing downwards) and Before the 4 screws are tightened insert into the opening in the extractor down, align the extractor hood properly.
  • Page 20 Notes...
  • Page 21 Notes...
  • Page 22 Notes...
  • Page 23 Z5114X5 351210...
  • Page 24 NEFF (UK) Ltd. Grand Union House, Old Wolverton Road, Old Wolverton Milton Keynes, MK12 5PT Tel: 01908 328300 9000 164 892 Fax: 01908 328399 Printed in Germany 0406 Es.

This manual is also suitable for:

D99t6n0

Table of Contents