Viessmann VITODENS 200-W Installation And Service Instructions Manual page 63

Table of Contents

Advertisement

Fault codes
(cont.)
Fault code dis-
System characteristics
played
84
Burner in a fault state
85
Burner in a fault state
90
Control mode
91
Control mode
92
No solar DHW heating
93
Control mode
94
No solar DHW heating
95
Burner blocked
Cause
CO limit within appliance
exceeded
Gas supply insufficient
during calibration
Short circuit, temperature
sensor
/
Short circuit, temperature
sensor
Short circuit, collector
temperature sensor
Short circuit, collector re-
turn temperature sensor
Short circuit, cylinder tem-
perature sensor
CO limit exceeded
Troubleshooting
Measures
Check entire flue gas path for the
following:
Flue gas recirculation
Leaks
Flue gas back pressure caused
by water pocket (if flue system
fall is insufficient)
Constrictions
Blockages
Repair flue system if necessary.
Press reset button R.
Test static gas pressure and gas
flow pressure.
Check that on-site gas line and gas
flow switch are correctly sized.
Visually inspect gas train inlet and
strainer on the inlet side for con-
tamination.
Note
Contamination from a brazed gas
line, for example, can block up the
gas train strainer on the inlet side.
Press reset button R.
Check sensor
on solar control
/
module.
Check sensor
on solar control
module.
Check temperature sensor
solar control module or sensor on
the Vitosolic.
Check temperature sensor at ter-
minal S3 on the Vitosolic 100.
Check temperature sensor
solar control module or sensor on
the Vitosolic.
Danger
An increased concentration
of carbon monoxide can
cause potentially fatal car-
bon monoxide poisoning.
Observe the safety instruc-
tions at the beginning of this
manual.
Determine the cause of the in-
creased CO level. Remedy the
fault.
Press Test on the CO limiter. The
alarm is switched off.
The burner starts again once the
CO level is below the CO limit.
&
on
on
%
63