Troubleshooting Guide - Caple LC600WH Instruction Manual

Wall chimney hoods
Table of Contents

Advertisement

Trouble Shooting Guide
Problem
Hood doesn't turn on.
Poor Airflow
Hood is vibrating
Motor running but no
air flow
Motor stops after a few
minutes
Strong cooking smell.
Oil dripping onto stove.
Whirring sound
Lights are working but
fan isn't
Fan is working but lights
are not
GUARANTEE AND SERVICE!
Before booking a service call,read the Trouble Shooting Guide above , for more information on
guarantee and service conditions, please contact local dealer.
Possible Reason
No electrical supply.
Power cord is damaged
Aluminum grease filters clogged
Charcoal filters clogged.
Re-circulating mode only.
Hood is not secured in place
Butterfly valve jammed.
High temperature safety device
activated.
The hood is installed too near the
cooking surface.
Fan speed too low
Charcoal filters not installed.
Aluminum grease filter satu rated.
Something in contact with fan blade.
Solution
Check the plug is connect ed.
Check the main switch is turned
on.
Contact your service technician
Clean the filters and replace
when dry.
Replace the charcoal filters.
Check the installation of hood.
Tighten mounting screws.
Contact your service technician
The kitchen is not sufficient ly
ventilated.
The hood must be at least
61cm (24") from the stove
Use one of the higher set tings.
In re-circulating mode, char coal
filters must be installed.
Wash the aluminum grease
filters
Contact your service technician
Contact your service technician
Contact your service technician

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc600bk