POWER ON
DRIVE SELECT
MOTOR ON
250 MILLISECONDS
MAXIMUM
INDEX
500 NANOSECONDS
MAXIMUM
TRACK 0
500 NANOSECONDS
MAXIMUM
WRITE PROTECT
SIDE SELECT
DIRECTION
STEP
WRITE ENABLE
ERASE GATE
(TUNNEL ERASE)
WRITE DATA
READ DATA
250 MILLISECONDS
MINIMUM
*FOR REFERENCE ONLY
100 MILLISECONDS
MINIMUM
u
5 MILLISECONDS
MINIMUM
200 NANOSECONDS
MINIMUM
100 NANOSECONDS_Lj
MINIMUM
| 1
250 MILLISECONDS
MINIMUM
390 MICROSECONDS4
200 NANOSECONDS
MINIMUM
I 2100 NANOSECONDS
| MAXIMUM
100 MICROSECONDS
MINIMUM
|
4 MICROSECONDS—4
FIGURE 3-2
CONTROL AND DATA TIMING REQUIREMENTS
200 ±3
MILLISECONDS
100 NANOSECONDS
-H
MINIMUM
100
NANOSECONDS
MINIMUM
u u
K-
H
900 MICROSECONDS
uuir'^u
-H
L r u i r n j u
8 MICROSECONDS
3-6
41
4 t
4 f
4 $ ■
4 MILLISECONDS*
4
<r
4 I-
4 fr
i
r
U
-----
20 MILLISECONDS
MAXIMUM
1
I
4 MICROSECONDS
8 MICROSECONDS
M
----------------
1 MICROSECOND
+ 250 NANOSECONDS