Please read this manual completely before attempting to install or operate this equipment.
UNDERCOUNTER REFRIGERATORS
MUR-20S-N6
MUR-24S-N6
MUR-27S-N6
MUR-34S-N6
WORKTOP REFRIGERATORS
MWR-20S-N6
MWR-24S-N6
MWR-27S-N6
MWR-34S-N6
GLASS DOOR REFRIGERATORS
MUR-20SG-N6
PREP TABLE REFRIGERATORS
MST-24S-N6
WARNING: This product can expose you to chemicals including Bisphenol A(BPA)
and Di(2-ethylhexyl)phthalate(DEHP) and Cobalt sulfate heptahydrate, which are
known to the State of California to cause cancer and birth defects or other reproductive
harm. For more information go to www.P65Warnings.ca.gov
AVERTISSEMENT:
Cancer ET Troubles de l'appareil reproducteur - www.P65Warnings.ca.gov
www.turboairinc.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MUR-20S-N6 and is the answer not in the manual?

Questions and answers

Summary of Contents for Turbo Air MUR-20S-N6

  • Page 1 Turbo Air Speeds up the Pace of Innovation Shallow Depth Refrigerators Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment. UNDERCOUNTER REFRIGERATORS MUR-20S-N6 MUR-24S-N6 MUR-27S-N6 MUR-34S-N6 WORKTOP REFRIGERATORS MWR-20S-N6 MWR-24S-N6 MWR-27S-N6 MWR-34S-N6...
  • Page 2: Table Of Contents

    CONTENTS PAGE NOTICE FOR HYDROCARBON REFRIGERATION UNITS 4 - 5 IMPORTANT SAFETY INFORMATION 6 - 9 SPECIFICATION / SERIAL NUMBER NOTICE TO CUSTOMER / INSTALLATION CLEANING / CAUTION OPERATION AND DISPLAY PANEL 13-14 INSTALLATION OF CASTERS INSTALLATION OF DRAIN PAN TROUBLESHOOTING STAINLESS STEEL EQUIPMENT CARE &...
  • Page 3: Notice

    NOTICE • This equipment is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instructions concerning the use of this equipment and the hazards involved by a person responsible for their safety. •...
  • Page 4: For Hydrocarbon Refrigeration Units

    FOR HYDROCARBON REFRIGERATION UNITS WARNING This unit uses R-290 (propane), or R-600a (isobutane) as a refrigerant. These hydrocarbon refrigerants are highly environmentally compatible but also are flammable and combustible. Please read this manual thoroughly before installing and operating the unit. Please take cautious measures to avoid risk of fire or explosion. PLEASE REFER TO THE LABEL INSIDE THE CABINET TO CHECK REFRIGERATION TYPE AND VOLUME.
  • Page 5 FOR HYDROCARBON REFRIGERATION UNITS WARNING • Handle the unit with care in order to avoid any serious damage to the refrigeration system. • The refrigerant tubing, condenser, and evaporator coils are easily prone to damage while handling, moving, installing, and cleaning the unit, which may lead to fire or even explosion.
  • Page 6: Important Safety Information

    IMPORTANT SAFETY INFORMATION SAFETY PRECAUTIONS To avoid any risk of fire, explosion, electric shock, personal injury, material damage or incorrect use of the appliance, be sure to observe the following safety precautions. (After reading these owner’s manual instructions, please keep the manual booklet in a safe place for reference.
  • Page 7 IMPORTANT SAFETY INFORMATION INSTALLATION & USAGE WARNING • Do not install the unit in a damp place where it could be splashed with water. Incorrect insulation of the electrical parts may cause fire or electric shock. • Do not plug several appliances into the same sockets. This could cause fire due to overheating.
  • Page 8 IMPORTANT SAFETY INFORMATION INSTALLATION & USAGE CAUTION • There is a risk of death from suffocation if a child puts the packing materials on his or her head. • Do not store any articles on top of the appliance. Articles may fall while opening or closing the door, and could cause personal injury or material damage.
  • Page 9 IMPORTANT SAFETY INFORMATION PROPER DISPOSAL OF OLD APPLIANCE For environmental purposes, refrigeration appliances must be properly disposed. This applies to your old appliance, and at the end of its service life, for your new appliance as well. WARNING Before disposing of old appliances, make them inoperable. Remove plug from mains, severe the power cable, and remove or destroy any snap or latch closures.
  • Page 10: Specification / Serial Number

    SPECIFICATIONS Shallow Depth Table Unit MODEL V/Hz REFRIGERANT AMPS WEIGHT (lbs) MUR-20S-N6 R-600a 115V/60Hz MUR-24S-N6 115V/60Hz R-600a MUR-27S-N6 115V/60Hz R-600a MUR-34S-N6 115V/60Hz R-600a MWR-20S-N6 115V/60Hz R-600a MWR-24S-N6 115V/60Hz R-600a MWR-27S-N6 115V/60Hz R-600a MWR-34S-N6 115V/60Hz R-600a MUR-20SG-N6 115V/60Hz R-600a 2.43 MST-24S-N6...
  • Page 11: Notice To Customer / Installation

    Insufficient space causes vibration noise, inefficient refrigeration, damage to the refrigeration system, and the waste of electricity (Turbo Air recommends that the rear of the unit should be no less than 5 inches from the wall).
  • Page 12: Cleaning / Caution

    CLEANING Before cleaning, unplug the unit and disconnect the power. Wipe and clean the inside and outside of appliance with a damp cloth. 1. CLEANING THE INTERIOR AND EXTERIOR - The interior and exterior of the unit can be cleaned using warm water and soap. - Do not use an abrasive cleaner because it will scratch the surface.
  • Page 13: Operation And Display Panel

    OPERATION AND DISPLAY PANEL MWR-24S-N6 Model: MUR-20S-N6 MUR-34S-N6 MWR-27S-N6 MUR-20SG-N6 MUR-24S-N6 MWR-34S-N6 MWR-20S-N6 MUR-27S-N6 1. INTRODUCTION OF KEY FUNCTION Button name Function Action Set parameters Press if for 3 sec. Switch between menu and parameters Press it and the controller responds.
  • Page 14 OPERATION AND DISPLAY PANEL Model: MST-24S-N6 1. Plug unit into the correct outlet. The power switch is located on the back side of the unit. Flip the power switch ON. Display panel should light up if these steps are followed correctly. 2.
  • Page 15: Installation Of Casters

    INSTALLATION OF CASTERS 1) Screw the caster (rear side) and the caster brakes (front side) by using caster wrench. 2) Use the caster shims to level the cabinet, if necessary, by inserting them to stems of the casters. CASTER (2EA) DRAIN PAN CASTER (WITH BRAKE) (2EA)
  • Page 16: Installation Of Drain Pan

    2) When installing the drain pan in the compressor mounted base, slightly lift vaporizing pipe to place the pan. HYE105MGU72a LABLE Drain Pan CASTER DRAIN PAN Model MUR-20S-N6 MWR-20S-N6 MUR-24S-N6 MWR-24S-N6 MUR-27S-N6 MWR-27S-N6 Model MUR-34S-N6 MWR-34S-N6...
  • Page 17: Troubleshooting

    TROUBLESHOOTING SYMPTOMS CAUSES SOLUTIONS • Thermostat set too cold. • Turn the thermostat setting Cooler is freezing to a higher temperature food. position. The unit does not • There is a power connection • Check the power cord and refrigerate at all. failure problem.
  • Page 18: Stainless Steel Equipment Care & Cleaning

    STAINLESS STEEL EQUIPMENT CARE AND CLEANING CAUTION: Do not use any steel wool, abrasive or chlorine based products to clean stainless steel surfaces. There are three basic things which can break down your stainless steel’s passivity layer and allow corrosion to occur. 1) Scratches from wire brushes, scrapers, and steel pads are just a few examples of items that can be abrasive to stainless steel’s surface.
  • Page 19 STAINLESS STEEL EQUIPMENT CARE AND CLEANING 4. Water Treatment To reduce deposits, soften the hard water when possible. Installation of certain filters can remove corrosive and distasteful elements. Salts in a properly maintained water softener can be to your advantage. Contact a treatment specialist if you are not sure of the proper water treatment.
  • Page 20: Warranty Information

    Air and upon proper installation* (indoor building only) and start-up in accordance with the instruction packet supplied with each Turbo air unit. Turbo Air s obligation under this warranty is limited to a period of three (3) years from the date of original installation or thirty nine (39) months after shipment date from Turbo Air, whichever occurs first.
  • Page 21 WARRANTY INFORMATION What is Not Covered by This Warranty... Turbo Air’s sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below. This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty.
  • Page 22 NOTE...
  • Page 23: Warranty Registration Card

    Address: (Street / Unit #) (City) (State) (Zip Code) hereby inform and certify to Turbo Air Inc. (Manufacturer) that the product model (Owner’s Name) and serial number mentioned above was purchased on from (Date of Purchase) (Name of the Dealer) Turbo Air Inc.
  • Page 24 4184 E. Conant St., Long Beach, CA 90808 Toll Free: 1-800-381-7770 Fax: 310-900-1033 Email: warranty@turboairinc.com www.turboairinc.com...

Table of Contents