5.12 Blow Function Setting
Blow function: After the unit is turned off, water in evaporator of indoor unit will be automatically evaporated to
avoid mildew.
In cooling and dry mode, press Function button till the unit enters dry function, BLOW blinking,
and then press Enter/Cancel button to turn on this function.
In blow mode, press Function button till the unit enters blow function and then press Enter/
Cancel button to cancel this function.
Blow function setting is shown in Fig.5.12
Turn on the unit, without
turning on blow function
Note:
1. After setting blow function, turn off the unit by pressing On/Off button or remote controller, indoor fan will
run at low fan speed for 10 min. (BLOW shows). Meanwhile, if blow function is canceled, indoor fan will be
turned off directly.
2. There is no BLOW function in fan or heating mode.
English
Press "Function" button
into blow function
Press "Enter/Cancel" button
to turn off blow function
Fig.5.12 Blow function setting
Press "Enter/Cancel" button
to turn on blow function
Press "Function" button
into blow function
19
Need help?