Nibe AHP S Installer Manual

Nibe AHP S Installer Manual

Accumulator tank
Hide thumbs Also See for AHP S:

Advertisement

Quick Links

IHB EN 1911-1
531217
Accumulator tank
AHP S/ AHPS S/ AHPH S
INSTALLER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AHP S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nibe AHP S

  • Page 1 IHB EN 1911-1 INSTALLER MANUAL 531217 Accumulator tank AHP S/ AHPS S/ AHPH S...
  • Page 3: Table Of Contents

    5 Electrical installation Sensors 6 Commissioning and adjusting Filling and venting 7 Service Service actions 8 Technical data Diagram Dimensions and setting-out coordinates Technical specifications Energy labelling Item register Contact information AHP S/ AHPS S/ AHPH S Table of Contents...
  • Page 4: Important Information

    . Caution This symbol indicates important information about what you should consider when installing or servicing the installation. This symbol indicates tips on how to facilitate using the product. Chapter 1 | Important information AHP S/ AHPS S/ AHPH S...
  • Page 5: General

    General AHP S/ AHPS S/ AHPH S is designed and manufactured according to good technical practice in order to ensure safe usage. Pressure Equipment Directive 2014/68/EU Article 4 point 3. SERIAL NUMBER The serial number can be found at the bottom right of the front cover.
  • Page 6 Shut off valves Expansion vessel Safety valve Hot water (page Shut off valves Mixing valve Safety valve Cold water (page Shut off valves Non-return valve Electricity (page 17) Sensors Chapter 1 | Important information AHP S/ AHPS S/ AHPH S...
  • Page 7: Delivery And Handling

    22xG¾ • The accumulator tank may only be installed vertically. 5 - 40 mm • The area where the AHP S/ AHPS S/ AHPH S is loc- LOCATION ated must be frost-proof and equipped with a floor The kit of supplied items is placed on top of the product.
  • Page 8: Removing The Covers

    Remove the screws from the upper and lower edges. Twist the cover slightly outward. Move the hatch backwards and slightly to the side. Pull the cover to one side. Pull the hatch forwards. Chapter 2 | Delivery and handling AHP S/ AHPS S/ AHPH S...
  • Page 9: Accumulator Tank Design

    3 Accumulator tank design AHP S300 AHPS S300 XL45 XL13 XL45 XL46 XL14 XL19 XL19 AHP S/ AHPS S/ AHPH S Chapter 3 | Accumulator tank design...
  • Page 10 Hot water sensor (control) Miscellaneous Rating plate Serial number plate Adjustable feet *or another external heat source Designations in component locations according to standard IEC 81346-1 and 81346-2. XL19 Chapter 3 | Accumulator tank design AHP S/ AHPS S/ AHPH S...
  • Page 11: Pipe Connections

    0.5 bar . Internal volume in AHP S/ AHPS S/ AHPH S for calculat- ing expansion vessel is 270 l. The expansion vessel's volume must be at least 10% of the system's total volume.
  • Page 12: System Diagram

    Docking connection, return line (to heat source) XL45 Docking connection, top of the tank XL46 Docking connection, middle of the tank *or another external heat source XL19 AHPH S300 XL46 XL19 Chapter 4 | Pipe connections AHP S/ AHPS S/ AHPH S...
  • Page 13: Dimensions And Pipe Connections

    *or another external heat source pump*) XL13Solar supply line Ø XL14Solar return line XL19Docking connection, return line high ext. temperature XL45Docking connection, level 1 XL46Docking connection, level 2 *or another external heat source AHP S/ AHPS S/ AHPH S Chapter 4 | Pipe connections...
  • Page 14 XL8Docking connection, supply line (from ext. heat pump*) XL9Docking connection, return line (to heat ext. pump*) XL19Docking connection, return line high ext. temperature XL46Docking connection, level 2 ext. *or another external heat source Chapter 4 | Pipe connections AHP S/ AHPS S/ AHPH S...
  • Page 15: Installation Alternative

    This is the outline diagram. Actual installations AHPS S300 AHPH S300 must be planned according to applicable standards. AHP S/ AHPS S/ AHPH S can be connected in several different ways, some of which are shown here. Further option information is available at nibe.eu and in the respective assembly instructions for the heat sources used.
  • Page 16 TO GROUND SOURCE HEAT PUMP/EXTERNAL HEAT SOURCE AHPH S300 can be docked with another heat source, for example NIBE F1145/1155. Chapter 4 | Pipe connections AHP S/ AHPS S/ AHPH S...
  • Page 17: Electrical Installation

    Sensors AHP S/ AHPS S/ AHPH S can be supplemented with up to two hot water sensors. These are placed in the sub- merged tube for hot water sensor (UA1) and (UA2).
  • Page 18: Commissioning And Adjusting

    XL8 connection, the reservoir is full. AHPH S300 VENTING For installations with several AHP S/ AHPS S/ AHPH S it is important to vent the connection between the tanks. Vent through the externally mounted vent valve (CP2-QM 60) .
  • Page 19: Service

    (with hose) in the cold water connection (XL3). Drain the solar coil in AHPS S300 through the siphon (with hose) on the connection, return to solar heating system (XL14). XL19 AHP S/ AHPS S/ AHPH S Chapter 7 | Service...
  • Page 20: Technical Data Diagram

    (XL14). NOTE To achieve the stop temperatures in the dia- gram above, the “target temp” charge method must be selected in the heat pump’s control system. Chapter 8 | Technical data AHP S/ AHPS S/ AHPH S...
  • Page 21: Dimensions And Setting-Out Coordinates

    AHPS S300 Dimensions and setting-out coordinates AHP S300 AHP S/ AHPS S/ AHPH S Chapter 8 | Technical data...
  • Page 22 AHPH S300 Chapter 8 | Technical data AHP S/ AHPS S/ AHPH S...
  • Page 23: Technical Specifications

    Scale for the product’s efficiency class A+ to F. Tested according to standard EN 12897 Energy labelling Supplier NIBE Model AHP S300 AHPS S300 AHPH S300 Energy efficiency class Heat loss Volume AHP S/ AHPS S/ AHPH S Chapter 8 | Technical data...
  • Page 24: Item Register

    Safety information Filling and venting, 18 Inspection of the installation, 6 Connecting two tanks, 15 Marking, 4 Symbols on AHP S/ AHPS S/ AHPH S, 4 Delivery and handling, 7 Safety valve, 19 Assembly, 7 Sensors, 17 Removing the covers, 8...
  • Page 27: Contact Information

    Tel: +46 (0)433-27 3000 kuzmin@evan.ru info@nibe.se nibe-evan.ru nibe.se SWITZERLAND NIBE Wärmetechnik c/o ait Schweiz Industriepark, CH-6246 Altishofen Tel. +41 (0)58 252 21 00 info@nibe.ch nibe.ch For countries not mentioned in this list, contact NIBE Sweden or check nibe.eu for more information.
  • Page 28 WS release date: 2019-05-02 12:29 Publish date: 2019-05-15 08:05 This manual is a publication from NIBE Energy Systems. All product illustrations, facts and data are based on the available information at the time of the publication’s approval. NIBE Energy Systems makes reservations for any factual or printing errors in this manual.

This manual is also suitable for:

Ahps sAhph sAhp s300Ahps s300Ahph s300