4 PROCESS CONTROL switch
This selects the method of control of the internal
digital video processor.
REMOTE: Select this position to use an optional
BVR-50/50P Remote Control Unit for remote
control of the internal digital video processor.
MENU: Select this position to use setup menus to
change the settings for the internal digital video
processor.
LOCAL: Select this position to use the subsidiary
control panel to change the settings for the internal
digital video processor.
5 VIDEO knob and PRESET/MANUAL switch
The switch makes the selection described immediately
below. When it is set to MANUAL, you can use the
knob to adjust the video signal output level.
PRESET: Regardless of the position of the knob, the
video signal output level is set to the reference
value.
MANUAL: You can adjust the video signal output
level in the range ±3 dB.
You can change the adjustment range using
extended menu item 714.
6 CHROMA (chrominance) knob and PRESET/
MANUAL switch
The switch makes the selection described immediately
below. When it is set to MANUAL, you can use the
knob to adjust the chrominance signal output level.
PRESET: Regardless of the position of the knob, the
chrominance signal output level is set to the
reference value.
MANUAL: You can adjust the chrominance signal
output level in the range ±3 dB.
You can change the adjustment range using
extended menu item 714.
..........................................................................................................................................................................................................
1) IRE: A unit for representing a video level laid down by
the IRE (Institute of Radio Engineers). The IRE is now
the IEEE (Institute of Electrical and Electronic
Engineers).
7 SET UP/BLACK LEVEL knob and PRESET/
MANUAL switch
The switch makes the selection described immediately
below. When it is set to MANUAL, you can use the
knob to adjust the setup level (525/60 system) or black
level (625/50 system).
PRESET: Regardless of the position of the knob, the
setup level (525/60 system) or black level (625/50
system) is set to the reference value.
MANUAL: You can adjust the setup level (525/60
system) in the range ±30 IRE
(625/50 system) in the range ±210 mV.
8 CHROMA (chrominance) PHASE knob and
PRESET/MANUAL switch
The switch makes the selection described immediately
below. When it is set to MANUAL, you can use the
knob to adjust the chrominance phase (the phase
difference from a burst signal).
PRESET: Regardless of the position of the knob, the
chrominance phase is set to the reference value.
MANUAL: You can adjust the chrominance phase in
the range ±30˚.
9 SYNC knob
This adjusts the output signal sync phase with respect
to the input reference signal to this unit, in a range of
±15 µs.
Use this adjustment when the output phase of this unit
is not accurately aligned with the reference signal
phase, or when carrying out special effects editing with
this unit and other VTRs connected to a switcher or
other equipment.
!º SC (subcarrier) knob
This adjusts the output signal subcarrier phase with
respect to the input reference signal to this unit, in a
range of ±200 ns.
For editing with composite signals, use this adjustment
when the output phase of this unit with respect to the
phase of the reference signal is not accurately aligned
with the subcarrier phase. This adjustment does not
affect the output SCH (subcarrier - sync) phase, which
remains constant.
Chapter 2 Location and Function of Parts
1)
, or the black level