  • Page 1 AIRGOCLEAN 350 E ® OPERATING MANUAL AIR CLEANER...
  • Page 2: Table Of Contents

    Information about the device.......... 4 AirgoClean 350 E ® Transport and storage............ 5 Assembly and start-up............ 6 https://hub.trotec.com/?id=45127 Operation ................ 7 Safety Available accessories............ 10 Errors and faults.............. 10 Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity Maintenance ................ 11...
  • Page 3 • Check accessories and connection parts for possible Intended use damage prior to every use of the device. Do not use any Use the device for cleaning the air as well as for odour defective devices or device parts. elimination (ionization) in interior spaces only whilst adhering to •...
  • Page 4: Information About The Device

    Residual risks Information about the device Warning of electrical voltage Device description Work on the electrical components must only be The device serves to filter the room air with the aim of reducing carried out by an authorised specialist company! slight and medium contaminations and odours in order to Warning of electrical voltage improve the air quality.
  • Page 5: Transport And Storage

    Device depiction Designation Front view Air outlet Control panel Segment display Air inlet with prefilter and HEPA carbon filter Wheel Transport handle Air quality sensor Remote control Transport and storage Note If you store or transport the device improperly, the device may be damaged.
  • Page 6: Assembly And Start-Up

    • Only put up the device in an upright, stable position on firm Assembly and start-up ground. Scope of delivery • Do not create tripping hazards when laying the power cable or other electric cables, especially when positioning • 1 x Device the device in the middle of the room.
  • Page 7: Operation

    Designation Meaning Operation Speed button For setting the fan speed Note Auto button Switching the automatic mode on Avoid open doors and windows. or off PM2.5/Timer Control panel Indication of the particulate matter indication pollution in µg/m3 or the number of hours of the set timer (1 h –...
  • Page 8 Please proceed as follows to switch off the automatic mode: Switching the device on 1. Press the Auto button (21). Once you have completely installed the device as described in ð The Auto LED (16) goes out. The symbol for automatic the chapter Assembly and start-up, you can switch it on. 1.
  • Page 9 ð The PM2.5/Timer indication (22) shows the set number Switching the locking function on and off of hours of the timer. In night mode, the set number of The locking function prevents the buttons on the control panel hours is not displayed, but the symbol for night from being used.
  • Page 10: Available Accessories

    Ventilate the room. device is not starting, have the electrics checked by a specialist company or by Trotec. The Life of filter LEDs (24) do not show any bars: • Check the air inlets (4) and air outlets (1) for proper fit.
  • Page 11: Maintenance

    Maintenance intervals Maintenance Maintenance and care interval before every as needed at least every at least every at least every at least start-up 2 weeks 4 weeks 6 months annually Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt...
  • Page 12 Tasks which require the device to be opened must Note only be carried out by authorised specialist The lifetime of the HEPA carbon filters depends on the companies or by Trotec. ambient conditions and the application period of the device. Cleaning the housing •...
  • Page 13 Please proceed as follows on both sides of the device: 5. Insert the new HEPA carbon filter (35) into the device. 1. Remove the air inlet with the prefilter (4) from the device Make sure that the strips (36) are positioned on the by pressing Push. outside.
  • Page 14 3. Clean the filter using a slightly damp, soft, lint-free cloth. If Cleaning the pre-filters the filter is heavily contaminated, clean it with warm water The prefilters should be cleaned once a month. mixed with a neutral cleaning agent. To do so, please proceed as follows on both sides of the device: 1.
  • Page 15: Technical Annex

    You can also find out about other return options that apply for many EU countries on the website https://hub.trotec.com/?id=45090. Otherwise, please contact an official recycling centre for electronic and electrical equipment authorised for your country.
  • Page 16 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...