Summary of Contents for Trotec AIRGOCLEAN 11 E

  • Page 1 ® AIRGOCLEAN 11 E OPERATING MANUAL AIR CLEANER...
  • Page 2: Table Of Contents

    Information about the device.......... 4 ® Airgoclean 11 E Transport and storage............ 5 Assembly and start-up............ 6 https://hub.trotec.com/?id=44803 Operation ................ 7 Safety Available accessories............ 9 Read this manual carefully before starting or using the Errors and faults.............. 9 device. Always store the manual in the immediate vicinity Maintenance ................ 10...
  • Page 3 • Check accessories and connection parts for possible Improper use damage prior to every use of the device. Do not use any • Do not place the device on wet or flooded ground. defective devices or device parts. • Do not place any objects, e.g. clothing, on the device. •...
  • Page 4: Information About The Device

    Residual risks Information about the device Warning of electrical voltage Device description Work on the electrical components must only be The device serves to filter the room air with the aim of reducing carried out by an authorised specialist company! slight and medium contaminations and odours in order to Warning of electrical voltage improve the air quality.
  • Page 5: Transport And Storage

    Device depiction Transport and storage Front view Note If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device. Transport Before transporting the device, observe the following: • Switch the device off. •...
  • Page 6: Assembly And Start-Up

    • Do not create tripping hazards when laying the power Assembly and start-up cable or other electric cables, especially when positioning the device in the middle of the room. Use cable bridges. Scope of delivery • Make sure that extension cables are completely unrolled. •...
  • Page 7: Operation

    Switching the device on Operation Once you have completely installed the device as described in Note the Start-up chapter, you can switch it on. Avoid open doors and windows. Afterwards, only the on/off key (11) lights up and the device is in standby mode.
  • Page 8 Automatic mode Automatic switch-off ü The device is switched on. When in automatic mode, the device automatically detects the 1. Press the timer button (12) until the desired number of air quality. hours is shown on the hours LED (13). Please proceed as follows to set the automatic mode: ð...
  • Page 9: Available Accessories

    Your device still does not operate correctly after these device is not starting, have the electrics checked by a checks? specialist company or by Trotec. Please contact the customer service. If necessary, bring the The device is loud or vibrates: device to an authorised specialist electrical company or to •...
  • Page 10: Maintenance

    Maintenance interval Maintenance Maintenance and care interval before every as needed at least every at least every at least every at least start-up 2 weeks 4 weeks 4 months annually Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt...
  • Page 11 • The HEPA carbon filter has to be replaced as soon as it is must only be carried out by authorised specialist dirty. This is brought to light e.g. by a reduced capacity companies or by Trotec. (see chapter Errors and faults). Cleaning the housing •...
  • Page 12 2. Take the used HEPA carbon filter (17) out of the device. 6. Reassemble the bottom plate (16) and the device by turning the bottom plate in the Close direction of the arrow. Make sure that the two arrows of the marking (18) are positioned exactly on top of each other.
  • Page 13: Technical Annex

    For further return options provided by us please refer to our website https://de.trotec.com/shop/. The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms...