AIRGOCLEAN
140 E / AIRGOCLEAN
145 E
®
®
EN
OPERATING MANUAL
AIR CLEANER

Advertisement

Table of Contents
loading

Summary of Contents for Trotec AIRGOCLEAN 140 E

  • Page 1 AIRGOCLEAN 140 E / AIRGOCLEAN 145 E ® ® OPERATING MANUAL AIR CLEANER...
  • Page 2: Table Of Contents

    Information about the device.......... 4 AirgoClean ® 145 E Transport and storage............ 5 Assembly and start-up............ 6 https://hub.trotec.com/?id=45465 Operation ................ 8 Safety Available accessories............ 10 Errors and faults.............. 11 Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity Maintenance ................ 12...
  • Page 3 • Check accessories and connection parts for possible Intended use damage prior to every use of the device. Do not use any Use the device for cleaning the air as well as for odour defective devices or device parts. elimination (ionization) in interior spaces only whilst adhering to •...
  • Page 4: Information About The Device

    Residual risks Information about the device Warning of electrical voltage Device description Work on the electrical components must only be The device serves to filter the room air with the aim of reducing carried out by an authorised specialist company! slight and medium contaminations and odours in order to Warning of electrical voltage improve the air quality.
  • Page 5: Transport And Storage

    Device depiction Transport and storage Front view Note If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device. Transport To make the device easier to transport, it is fitted with a carry handle.
  • Page 6: Assembly And Start-Up

    Wall mounting Assembly and start-up 1. Mark the positions for the bore holes on the wall. Observe the minimum distances specified in the technical data. Scope of delivery • 1 x Device • 1 x HEPA carbon filter incl. pre-filter made of synthetic fibre •...
  • Page 7 3. Insert appropriate wall plugs into the bore holes depending Start-up on the type of wall. Position the holder on the wall as The HEPA carbon filter is pre-installed. shown and attach the holder in place with the 6 screws. Note Remove the plastic cover from the HEPA carbon filter. To insert the HEPA carbon filter, proceed as described under Changing the HEPA carbon filter.
  • Page 8: Operation

    Designation Meaning Operation PM2.5 colour Bar illumination changes colour = Note indicator automatic mode Avoid open doors and windows. Illuminated in different colours according to the measured air Control panel quality: • green = good • yellow = medium • red = poor PM2.5/Timer Indication of the fine dust pollution indication in µg/m3 or the number of hours...
  • Page 9 Please proceed as follows to switch off the automatic mode: Switching the device on 1. Press the Auto button (15). Once you have completely installed the device as described in ð The illumination of the Auto button (15) goes out. the chapter Assembly and start-up, you can switch it on. 1.
  • Page 10: Available Accessories

    Switching the locking function on and off Setting the timer The locking function prevents the buttons on the control panel The function can be set in all operating modes. from being used. The number of hours can be set from 1 h to 24 h. Please proceed as follows to lock the control panel: Automatic switch-off ü...
  • Page 11: Errors And Faults

    • Wait for 10 minutes before restarting the device. If the device is not starting, have the electrics checked by a specialist company or by Trotec. The device is loud or vibrates: • Check whether the device is set up in a stable and upright position.
  • Page 12: Maintenance

    Maintenance intervals Maintenance Maintenance and care interval before every as needed at least every at least every at least every at least start-up 2 weeks 4 weeks 6 months annually Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt...
  • Page 13 Tasks which require the device to be opened must Note only be carried out by authorised specialist The lifetime of the HEPA carbon filter depends on the companies or by Trotec. ambient conditions and the application period of the device. Cleaning the housing •...
  • Page 14 Please proceed as follows: 4. Insert the cleaned / new HEPA carbon filter (27) into the ü The device is switched off. device. Make sure that the strips (28) are positioned as 1. Fold out the device cover (26) towards the front. indicated. 2. Pull the strips (28) to take the HEPA carbon filter (27) out of the device.
  • Page 15 Cleaning the air quality sensor The air quality sensor(6) has to be cleaned every 3 months or once it is soiled (please also refer to the Chapter Operation and Chapter Errors and faults). 1. Clean the sensor cover using a soft, lint-free cloth. 2.
  • Page 16: Technical Annex

    You can also find out about other return options 240 m Fan stage II that apply for many EU countries on the website 330 m https://hub.trotec.com/?id=45090. Otherwise, please contact an Fan stage III (turbo mode) official recycling centre for electronic and electrical equipment Ambient temperature 0 °C to 35 °C authorised for your country.
  • Page 17 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...

This manual is also suitable for:

Airgoclean 145 e