Logging the wireless components onto the...
Fig. 5
Logging on the wireless outside temperature sensor
B
Fig. 6
Logging on the Vitotrol 200 RF and Vitotrol 300 RF
Relevant installation and service instructions,
chapter "Commissioning"
A
C
(cont.)
2. Place all wireless components near the wireless
base station.
Note
If a wireless repeater is used, position this at least
1 m away from the wireless base station.
3. Start the Vitotronic control unit.
4. Log on the wireless components one at a time with
key
(see the following chapter).
A
1. Open the enclosure of the outside temperature sen-
sor.
2. Wireless base station (see fig. 5):
Press key
:
A
Operation without wireless repeater: for 4 s
■
LED flashes green at long intervals.
■
Operation with wireless repeater: for 8 s
LED flashes green at short intervals.
3. Wireless outside temperature sensor:
Briefly press key
.
B
LED
C
flashes red.
If the log on was successful, the green LED on the
wireless base station lights up.
Installation sequence