Page 2
Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
Operating distances Lateral and vertical offset Wiring Pin assignment Requirements and connection to evaluation devices Installation Adjustment Periodic test Dimensions in mm Technical details Safety characteristic data Order reference System Accessories EC declaration of conformity Operating Manual PSEN ma2.1p-11/-31 22191-EN-02...
PSEN ma2.1p-11/-31 Introduction Validity of documentation This documentation is valid for the product PSEN ma2.1p-11/-31. It is valid until new docu- mentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
If installed in other environments, measures should be taken to comply with the applicable standards and directives for the respective installation site with regard to in- terference. Operating Manual PSEN ma2.1p-11/-31 22191-EN-02...
In safety-related applications, please comply with the mission time T in the safety-re- lated characteristic data. When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PSEN ma2.1p-11/-31 22191-EN-02...
The N/O contact is closed and the N/C contact is opened. The safety switch can be used in series connections. Operate the PSEN ma2.1p-11/-31 in conjunction with the following components: Actuator PSEN 2.1-10(see Order reference [...
PSEN ma2.1p-11/-31 Lateral and vertical offset Legend [1] Lateral offset [2] Vertical offset Safety switch PSEN ma2.1p-11 Assured operating distance S in mm Lateral offset Vertical offset The stated values are valid at a temperature of 20 °C. Safety switch PSEN ma2.1p-31...
Blue [3+] Black Requirements and connection to evaluation devices For use of PSEN ma2.1p-11/-31 in accordance with DIN EN 60947-5-3 an evaluation device must be connected. Connect the PSEN ma2.1p-11/-31 either with a certified Pilz evaluation device or with an evaluation device with defined properties...
Page 11
FS_Safety Gate PSSuniversal PLC for safety gate monitoring with function block FS_SafetyGate A full list of the certified Pilz evaluation devices (type examination certificate) is available in the download area (http://www.pilz.com/support/downloads). The correct connection to the respective evaluation device is described in the operating manual for the evaluation device.
Page 12
23 24 33 34 43 44 11 12 21 22 31 32 41 11 12 21 22 33 34 43 44 PSENmag Fig.: Dual-channel connection of four PSENmag to the input circuits of an evaluation device Operating Manual PSEN ma2.1p-11/-31 22191-EN-02...
PSEN ma2.1p-11/-31 Examples for connection to Pilz evaluation devices: PNOZmulti PSENmag PSEN i1 Brown White Blue Black Legend I0 Input OSSD I1 Input OSSD T1, T2 Test pulse outputs Installation CAUTION! Potential loss of safety function due to changed device properties The unit's properties may be affected if installed in an environment contain- ing electrically or magnetically conductive material.
The protection type (see Technical details [ 15]) can only be achieved by using the Pilz connection leads available as an accessory. Adjustment The safety switch may only be used with the corresponding actuator PSEN 2.1-10. Always test the function with series connections with the PSEN i1 interface and connec- ted evaluation device.
Design in accordance with EN ISO 14119 Classification in accordance with EN 60947-5-3 PDDB PDDB Electrical data 506406 506408 Supply voltage Voltage 24 V 24 V Kind Voltage tolerance -20 %/+20 % -20 %/+20 % Operating Manual PSEN ma2.1p-11/-31 22191-EN-02...
Page 16
Min. operating distance Somin 0,5 mm 0,5 mm Typical operating distance So 4,5 mm 8 mm Assured release distance Sar 19 mm 25 mm Typical release distance Sr 6,5 mm 10 mm Repetition accuracy switching distances Operating Manual PSEN ma2.1p-11/-31 22191-EN-02...
You must comply with the safety-related characteristic data in order to achieve the required safety level for your plant/machine. Safety characteristic data B10d in accordance with EN ISO 13849-1: 2015 and EN 62061 2.000.000 TM [year] in accordance with EN ISO 13849-1:2015 Operating Manual PSEN ma2.1p-11/-31 22191-EN-02...
European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost- fildern, Germany Operating Manual PSEN ma2.1p-11/-31...
Page 20
Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95446300 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30...
Need help?
Do you have a question about the PSEN ma2.1p-11 and is the answer not in the manual?