PSEN ma1.3-22 M12/8 VA
}
PSEN sensor technology
Operating Manual-1004511-EN-04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSEN ma1.3-22 M12/8 VA and is the answer not in the manual?

Questions and answers

Summary of Contents for Pilz PSEN ma1.3-22 M12/8 VA

  • Page 1 PSEN ma1.3-22 M12/8 VA PSEN sensor technology Operating Manual-1004511-EN-04...
  • Page 2 We do assure you that all persons are regarded without discrim- ination and on an equal basis. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    Dimensions in mm .........................20 Technical details ........................20 Safety characteristic data......................22 Supplementary data .......................23 Technical details PSEN ix0 F1 mag..................23 Order reference ........................24 System ............................24 Accessories..........................24 EC declaration of conformity ....................25 UKCA-Declaration of Conformity ..................25 Operating Manual PSEN ma1.3-22 M12/8 VA 1004511-EN-04...
  • Page 4: Introduction

    PSEN ma1.3-22 M12/8 VA Introduction Validity of documentation This documentation is valid for the product PSEN ma1.3-22 M12/8 VA. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5: Safety

    If installed in other environments, measures should be taken to comply with the applicable standards and directives for the respective installation site with regard to in- terference. Operating Manual PSEN ma1.3-22 M12/8 VA 1004511-EN-04...
  • Page 6: Safety Regulations

    In safety-related applications, please comply with the mission time T in the safety-related characteristic data. When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PSEN ma1.3-22 M12/8 VA 1004511-EN-04...
  • Page 7: For Your Safety

    1 auxiliary contact (N/O) Design: cylindrical with threaded sleeve – Safety switch M12 – Actuator M12: PSEN ma1.3-08 VA Operation Magnetic Switching voltage 24 VDC Series connection via PSEN ix1 interface Switch and actuator from stainless steel Operating Manual PSEN ma1.3-22 M12/8 VA 1004511-EN-04...
  • Page 8: Function Description

    If the actuator is within the response range (safety gate closed), the safety contacts and the auxiliary contact on the safety switch are closed. Application in series connections Operate the PSEN ma1.3-22 M12/8 VA in conjunction with the following components: Actuator PSEN ma1.3-08 VA (see Order reference [...
  • Page 9: Operating Distances

    Assured release distance The offset-independent values for the switching distances are included in the Technical details [ 20]. Lateral and vertical offset Actuator PSEN ma1.3-08/VA Legend [1] Lateral offset [2] Vertical offset [3] Sensing faces Operating Manual PSEN ma1.3-22 M12/8 VA 1004511-EN-04...
  • Page 10: Wiring

    UL requirement: the supply voltage must be provided via a Class 2 power supply. Pin assignment NOTICE The colour marking for the connection lead only applies for the cable that Pilz supplies as an accessory The safety switch is shown in an unoperated condition. Operating Manual PSEN ma1.3-22 M12/8 VA | 10 1004511-EN-04...
  • Page 11: Requirements And Connection To Evaluation Devices

    – can be connected in series – may not be used for safety circuits Requirements and connection to evaluation devices For use of PSEN ma1.3-22 M12/8 VA in accordance with DIN EN 60947-5-3 an evaluation device must be connected. Connect the PSEN ma1.3-22 M12/8 VA...
  • Page 12 The risk time is made up of the reaction time of the sensor (see Technical details [ 20]) and the processing and delay times of the evaluation device (s. operating manual for the relevant evaluation device). Operating Manual PSEN ma1.3-22 M12/8 VA | 12 1004511-EN-04...
  • Page 13 43 44 21 22 31 32 41 11 12 11 12 21 22 33 34 43 44 PSENmag Fig.: Dual-channel connection of four PSENmag to the input circuits of an evaluation device Operating Manual PSEN ma1.3-22 M12/8 VA | 13 1004511-EN-04...
  • Page 14 PSEN ma1.3-22 M12/8 VA Examples for connection to Pilz evaluation devices: Application in series connections PSENmag PNOZ s3 PSEN ix1 White Green Yellow Pink PNOZmulti PSENmag PSEN ix1 White Green Yellow Pink Operating Manual PSEN ma1.3-22 M12/8 VA | 14...
  • Page 15 PSEN ma1.3-22 M12/8 VA Application in single connections PSENmag PNOZ s3 White PSEN ix0 F1 mag Green Yellow Pink PSENmag PNOZmulti White PSEN ix0 F1 mag Green Yellow Pink Operating Manual PSEN ma1.3-22 M12/8 VA | 15 1004511-EN-04...
  • Page 16: Installation

    The fastening of safety switch and actuator has to be sufficiently stable to ensure the proper operation of the safety switch and the actuator. The distance between two safety switches must be maintained (see Technical details [ 20]). Operating Manual PSEN ma1.3-22 M12/8 VA | 16 1004511-EN-04...
  • Page 17 Do not apply any installation tools (e.g. Pliers) on the surfaces of the switch. The protection type (see Technical details [ 20]) is only achieved when Pilz connec- tion cables are used - these are available as an accessory - and when the connector torque is complied with (see Technical details).
  • Page 18 Sensing face Attach the actuator using 2 M12x1 hexagonal nuts. Also note the max. torque setting (see Technical details [ 20]). Operating Manual PSEN ma1.3-22 M12/8 VA | 18 1004511-EN-04...
  • Page 19: Adjustment

    Always test the function with the PSEN ix1 interface and connected evaluation device. Application in single connections Always test the function with the control cabinet terminal PSEN ix0 F1 mag and connec- ted evaluation device. Operating Manual PSEN ma1.3-22 M12/8 VA | 19 1004511-EN-04...
  • Page 20: Dimensions In Mm

    140 mA Utilisation category in accordance with EN 60947-1 DC-12 Conventional thermal current auxiliary contact 0,1 A Max. continuous current safety contacts 0,1 A Times Reaction time (actuator removed) 2 ms Operating Manual PSEN ma1.3-22 M12/8 VA | 20 1004511-EN-04...
  • Page 21 Sensor flush installation in accordance with EN 60947-5-2 yes, follow installation guidelines Connection type M12, 8-pin male connector Material Stainless steel 1.4401 Max. torque setting Safety switch 20 Nm Actuator 1 20 Nm Connector 0,6 Nm Operating Manual PSEN ma1.3-22 M12/8 VA | 21 1004511-EN-04...
  • Page 22: Safety Characteristic Data

    Operating mode B10d in accordance with EN ISO TM [year] in accordance with EN 13849-1: 2015 and EN 62061 ISO 13849-1:2015 2-channel, ≤ 15 mA 50.000.000 2-channel, > 15 mA 34.000.000 Operating Manual PSEN ma1.3-22 M12/8 VA | 22 1004511-EN-04...
  • Page 23: Supplementary Data

    Flexible with/without crimp connector 0,08 - 2,5 mm², 28 - 14 AWG Stripping length with spring-loaded terminals 5 - 6 mm Dimensions Height 56 mm Width 7 mm Depth 91 mm Weight 25 g Operating Manual PSEN ma1.3-22 M12/8 VA | 23 1004511-EN-04...
  • Page 24: Order Reference

    PSEN ma Single connection Product type Features Order no. PSEN ix0 F1 mag Control cabinet terminal for use of 535109 the PSEN ma1.3-22 M12/8 VA in single connections Operating Manual PSEN ma1.3-22 M12/8 VA | 24 1004511-EN-04...
  • Page 25: Ec Declaration Of Conformity

    This product/these products meet the requirements of the directive 2006/42/EC for ma- chinery of the European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Authorised representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ostfildern, Germany UKCA-Declaration of Conformity This product(s) complies with following UK legislation: Supply of Machinery (Safety) Regu- lation 2008.
  • Page 26 We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com, Internet: www.pilz.com...