  • Page 2 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
  • Page 3: Table Of Contents

    Wiring Pin assignment Requirements and connection to evaluation devices Installation Installation type 1 Installation type 2 Adjustment Periodic test Dimensions in mm Technical details Safety characteristic data Order reference System Accessories EC declaration of conformity Operating Manual PSEN ma1.4a-50 22120-EN-06...
  • Page 4: Introduction

    PSEN ma1.4a-50 Introduction Validity of documentation This documentation is valid for the product PSEN ma1.4a-50. It is valid until new document- ation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5: Safety

    In order to achieve the re- quired safety level for the overall plant/machine, define the safety requirements for the plant/machine and then define how these must be implemented from a technical and organ- isational standpoint. Operating Manual PSEN ma1.4a-50 22120-EN-06...
  • Page 6: Use Of Qualified Personnel

    – If spare actuators are used, these must be installed as described in Installation [ 12]. – If the original actuators are replaced with substitute actuators, the ori- ginal actuators must be destroyed before disposal. Operating Manual PSEN ma1.4a-50 22120-EN-06...
  • Page 7: Unit Features

    If the actuator is within the response range (safety gate closed), the safety contacts of the safety switch are closed. Operate the PSEN ma1.4a-50 in conjunction with the following components: Actuator PSEN ma1.4-03 or actuator PSEN ma1.4-10 (see Order reference [...
  • Page 8: Operating Distances

    Lateral and vertical offset Legend [1] Lateral offset [2] Vertical offset Actuator PSEN ma1.4-03 Assured operating distance S in mm Lateral offset Vertical offset The stated values are valid at a temperature of 20 °C. Operating Manual PSEN ma1.4a-50 22120-EN-06...
  • Page 9: Wiring

    Pin assignment NOTICE The colour marking for the connection lead only applies for the cable that Pilz supplies as an accessory The safety switch is shown in an unoperated condition. brown Layout of the 4-core cable...
  • Page 10: Requirements And Connection To Evaluation Devices

    PSEN ma1.4a-50 Requirements and connection to evaluation devices For use of PSEN ma1.4a-50 in accordance with DIN EN 60947-5-3 an evaluation device must be connected. Connect the PSEN ma1.4a-50 either with a certified Pilz evaluation device or with an evaluation device with defined properties...
  • Page 11 (s. operating manual for the relevant evaluation device). PSENmag Evaluation device Input circuit Input circuit Fig.: Dual-channel connection PSEN ma1.4a-50 to the input circuits of an evaluation device Examples for connection to Pilz evaluation devices: PNOZ s3 PSENmag brown...
  • Page 12: Installation

    S can change. – Check the assured release distance S Safety switches and actuators must be positioned so that they are secured against a change of position. Operating Manual PSEN ma1.4a-50 22120-EN-06...
  • Page 13 4. Align actuator to sensor. INFORMATION The inscribed area on the actuator (sensing face) should face the sensor. 5. Slide the actuator on to the screws. 6. Align sensor and tighten screws with max. 0,8 Nm. Operating Manual PSEN ma1.4a-50 22120-EN-06...
  • Page 14: Installation Type 2

    11. Installation of sensor and actuator is now complete. INFORMATION Seals (1), (2), (3) meet the requirements of UL 94 V0, seal (4) does not meet UL requirements. Installation type 2 Install the sensor as shown for installation type 1 Operating Manual PSEN ma1.4a-50 22120-EN-06...
  • Page 15: Adjustment

    Seals (1), (2), (3) meet the requirements of UL 94 V0, seal (4) does not meet UL requirements. Adjustment The safety switch may only be used with the corresponding actuator PSEN ma1.4-03 or PSEN ma1.4-10. Always test the function with a connected evaluation device. Operating Manual PSEN ma1.4a-50 22120-EN-06...
  • Page 16: Periodic Test

    Classification in accordance with EN 60947-5-3 PDDB PDDB Electrical data 506320 506322 Supply voltage Voltage 24 V 24 V Kind -20 %/+20 % -20 %/+20 % Voltage tolerance Supply voltage Max. current 200 mA 200 mA Operating Manual PSEN ma1.4a-50 22120-EN-06...
  • Page 17 Typical operating distance So 3,5 mm 12,5 mm 12 mm 22 mm Assured release distance Sar Typical release distance Sr 6 mm 16 mm Repetition accuracy switching distances Min. distance between safety 50 mm 50 mm switches Operating Manual PSEN ma1.4a-50 22120-EN-06...
  • Page 18: Safety Characteristic Data

    You must comply with the safety-related characteristic data in order to achieve the required safety level for your plant/machine. B10d in accordance with EN ISO 13849-1: 2015 TM [year] in accordance with EN ISO and EN 62061 13849-1:2015 7.300.000 Operating Manual PSEN ma1.4a-50 22120-EN-06...
  • Page 19: Order Reference

    European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost- fildern, Germany Operating Manual PSEN ma1.4a-50...