Commissioning
Switch ON the mains to the heating circuit, slide the mode selector to continuously ON, and turn the thermostat dial
fully anticlockwise to maximum temperature. Both the heating ON indicator and the heating demand indicator will
come ON (assuming the floor temperature is not above 30°C). If the thermostat dial is now gradually turned clockwise
the heating demand indicator will turn OFF. Turning the dial approximately 2.0°C anticlockwise will bring the heating
demand indicator ON again.
Remember to use the lowest setting of the thermostat dial consistent with comfort as significant savings on heating bills
can be made by a reduction of 1°C. The unit should now be programmed using either the UFPT24 or UFPT7
programming instructions.
UFPT24 Programming Instructions
3
24 hour digital
Change Button
clock display
sets days, hours, and minutes
and self cancelling override
Program Button
ON
selects clock and ON/OFF
CHANGE
PROGRAM
PROGRAM
1 2 3 4
times and review
ON
OFF AUTO
Indicator showing when timed
output is ON or unit is
Output status showing if
continuosly ON.
HEATING ON
unit is ON or OFF