• ELECTRONIC CIRCUIT BOARD

®
LEONARDO
is a combustion safety and control system which allows optimal performance in all
conditions thanks to two sensors measuring the pressure level in the combustion chamber and smoke
temperature.
The detection of and subsequent optimisation of these two parameters is continuous in order to correct
operation anomalies in real time.
The LEONARDO
®
system offers constant combustion, automatically regulating the draft based on the
characteristics of the chimney ue (bends, length, shape, diameter, etc..) and environmental conditions
(wind, humidity, atmospheric pressure, installations at high altitude, etc.).
The standards for installation must be respected. LEONARDO
type of pellets and automatically djust the ow moment by moment to ensure the required level of
combustion.
• ELECTRONIC CIRCUIT BOARD
socket
RS323
SERIAL PORT
The Dealer can install an optional on the AUX outlet for controlling the process of
switching on and off (e.g. telephone remote, local thermostat), located at the rear oh the
boiler-stove. Can be connected via special optional trestle (code 640560).
BACKUP BATTERY
A backup battery is found on the control board (3-Volt CR 2032 battery).
Its malfunction is indicated with the following messages (not considered a defect but
due to normal wear-and-tear): "Battery check".
For more detailed information, please contact the DEALER who has performed the rst
1st ignition.
FEATURES
®
consolle
screw rpm
Panel control
backup battery
lithium CR2032
Smoke expulsion motor
M SCREW
Outlet pump
- 27
system is also able to recognise the
ow sensor
Optional
boiler probe
thermocouple
smoke rpm
230 vac power
supply
50Hz +/-10%
Boiler circulator
(optional)
PORT BACK STOVE
FUSE two fuses are inserted in the so-
cket with switch, located on the back of
the boiler-stove, one of which operational
(*) and the other is held in reserve (* *).
-
Water outlet
probe
Vacuum gauge
Reading
points
* **