Codes
Code 2
(cont.)
Coding in the delivered condition
F1:0
Screed drying not active
F2:8
Time limit for party mode or exter-
nal operating program changeover
via pushbutton: 8 h
F8:-5
Temperature limit for terminating
reduced mode -5 °C; see example
on page 95.
Observe setting of coding address
"A3".
F9:-14
Temperature limit for raising the re-
duced set room temperature
-14 °C; see example on page 95.
FA:20
The set boiler water or flow tem-
perature is increased by 20 %
when changing from operation with
reduced room temperature to oper-
ation with standard room tempera-
ture. See example on page 96.
Fb:30
Duration of the set boiler water or
flow temperature increase (see
coding address "FA") 60 min. See
example on page 96.
In the "Heating and DHW" program, party mode ends automatically when the system changes over to operation at stand-
*2
ard room temperature.
76
Possible change
F1:1
to
F1:6
F1:15
F2:0
F2:1
*2
to
F2:12
F8:+10
to
F8:-60
F8:-61
F9:+10
to
F9:-60
FA:0
to
FA:50
Fb:0
to
Fb:150
Screed drying can be set with 6 ad-
justable temperature/time profiles
(see page 94)
Constant flow temperature 20 °C
No time limit for party mode
Time limit adjustable from 1 to 12 h
Temperature limit adjustable from
+10 to -60 °C
Function inactive
Temperature limit for raising the set
room temperature to the value se-
lected for standard mode adjustable
from
+10 to -60 °C
Temperature increase adjustable
from 0 to 50 %
Duration adjustable from
0 to 300 min;
1 step
2 min)
*2
*2