Eizo FlexScan L885 User Manual page 30

Color lcd monitor
Hide thumbs Also See for FlexScan L885:
Table of Contents

Advertisement

English
Adjustment Contents
Menu
Brightness
Temperature
(p.44)
Gamma (p.43)
Saturation
Hue
Gain (p.43)
6 colors
Reset
30
4. ADJUSTMENT
Function Descriptions
To set the brightness of the
screen
To set the color temperature
NOTE
The values shown in the Kelvin are available only as a reference tool.
Setting the temperature under 4,000 K or over 10,000 K invalidates the
color temperature setting. (The color temperature's setting turns "OFF".)
To set the gamma value
NOTE
If setting the gamma value, the using the monitor in the digital signal input
is recommended.
If using the monitor in the analog input signal, set the gamma value from
1.8 to 2.2.
To change the saturation
NOTE
Using <Saturation> adjustment may not obtain proper tone reproduction.
To change the flesh color, etc.
NOTE
Using <Hue> adjustment may not obtain proper tone reproduction.
To change each color (red, green
and blue)
NOTE
The values shown in the percentage are available only as a reference
tool.
Setting the <Temperature> (p.44) invalidates the <Gain> adjustment.
<Gain> setting returns to the default.
To adjust <Saturation> and
<Hue> in each color (Red, Yellow,
Green, Cyan, Blue and Magenta)
To return the color settings of the
selected mode to the default
settings
Adjustable range
0 ∼ 100%
4,000 ∼ 10,000 K
in 500 K increments (including
9,300 K). Default setting is off
(normal white)
1.4 ∼ 3.0
-16 ∼ 16
Setting the minimum level (-16)
turns the image to the
monochrome.
-20 ∼ 20
0 ∼ 100%
By adjusting the red, green and
blue color tones for each mode,
custom colors can be defined.
Display a white or gray background
image and adjust the <Gain>.
Hue: -20 ∼ 20
Saturation: -16 ∼ 16
Select the <Reset>.

Hide quick links:

Advertisement

Table of Contents
loading