5 – FUNCTIONING AND USE
5.After a while push FLUSHING in order to flush
the unit before stopping it.
Then the unit will stop after about 1 minute.
After completing the procedure, the system will be ready to start normally.

5.3 Normal operating procedure

Preliminary checks:
1. Reset valve closed (lever orthogonal to the body valve) and the positioner completely unscrewed.
2. Depressurization valve closed and grey valve on the active carbon filter open.
5.3.1

Normal operating procedure without final flushing

1. Push ON/OFF to start the watermaker.
2. Push ON/OFF to stop the watermaker.
CAUTION:
The watermaker produces periodic "beats" during its functioning, due to the movement of the internal
parts. A pressure peak is shown on the pressure gauge during these beats. Avoid to shut down the
watermaker exactly on the beat, but wait a second after the beat to stop the unit properly.
5.3.2

Normal operating procedure with final flushing (recommended procedure)

1. Push ON/OFF to start the watermaker.
2. Push FLUSHING to flush and stop the
watermaker. The watermaker will activate a
flushing cycle then it will stop after 1 minute
THE PRESENT MANUAL BELONGS TO -
Schenker Italia
- ALL RIGHTS RESERVED