Hayward XE Series Quick Start Manual

Hayward XE Series Quick Start Manual

Hide thumbs Also See for XE Series:

Advertisement

XE Pump Series

SIMPLE BUTTON PROGRAMMING

For detailed information
about XE Series Pumps,
scan this QR code
This illustration is showing TriStar
Energy Efficient
OVERRIDE MODE
START
HIGH
MEDIUM
3 hours
3 hours
Press for next speed
4 second hold
To EXIT
Press & Hold

QUICK START GUIDE

®
XE.
Variable Pump Speed
To ENTER
Press once
LOW
STOP
3 hours
No time limit
Light flashes slowly in
OVERRIDE MODE
Back to Daily Schedule
®
TriStar
XE | MaxFlo
Button & LED location
Programmable
WIRING INSTRUCTIONS
Hazardous Voltage: Always turn off power at the circuit breaker before wiring. The pump can be wired to
230 VAC (factory default) or 115 VAC supply. Move the jumper to the corresponding input voltage as shown.
230 VAC
(Default)
115 VAC
Solid
®
®
XE | Super Pump
XE

PUSH BUTTON

SHORT PRESS
Override mode /
4 second hold
PRESS & HOLD
Program mode /
Save & continue

STATUS LIGHT

SOLID LED
QUICK FLASHING
Program Mode Only
# blink indicates intervals
SLOW FLASHING
Override Mode Only
3 RAPID FLASHES
3x
Confirms press and hold
successful
QRG3200VSMD
Jumper in
230V position
L1
L2
Ground
Jumper in
115V position
L1
N
Ground

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XE Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hayward XE Series

  • Page 1 XE | Super Pump SIMPLE BUTTON PROGRAMMING PUSH BUTTON SHORT PRESS Override mode / Choose pump speed For detailed information about XE Series Pumps, scan this QR code 4 second hold PRESS & HOLD Program mode / ® This illustration is showing TriStar Save &...
  • Page 2 CHOOSE PUMP SPEED DAILY SCHEDULE PRESS FOR NEXT SPEED START START: POWER ON 100% DEFAULT DAILY SCHEDULE INTERVAL 1 INTERVAL 2 INTERVAL 3 24 hour 12 hours 8 hours 4 hours 50% Pump speed 50% Pump speed 50% Pump speed The pump will start at 100% speed for 8 minutes to prime HOW TO PROGRAM THE DAILY SCHEDULE INTERVAL 1...

This manual is also suitable for:

Tristar xeMaxflo xeSuper pump xe

Table of Contents