Page 3
NV9641 User’s Guide Electrostatic Discharge (ESD) Protection Electrostatic discharge occurs when electronic components are improperly handled and can result in intermittent failure or complete damage adversely affecting an electrical circuit. When you remove and replace any card from a frame always follow ESD-prevention procedures: •...
Page 4
Notices • Les cartes qui sont reliées à un châssis ou boîtier métallique mis à la terre ne nécessitent pas de protection antistatique spéciale. Précautions pour les écrans LCD et TFT Regarder l’écran pendant une trop longue période de temps peut nuire à votre vision.
Page 5
NV9641 User’s Guide • EN 61000-4-2 Electrostatic discharge immunity • EN 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity • EN 61000-4-4 Electrical fast transient immunity • EN 61000-4-5 Surge transient immunity • EN 61000-4-6 Conducted disturbances immunity • EN 61000-4-8 Power frequency magnetic field immunity •...
Preface Terms, Conventions and Abbreviations Use the ‘First Page’ , ‘Previous Page’ , and ‘Next Page’ , and ‘Last Page’ buttons to go to the first, previous, next, or last page within a PDF file. Note: To display the navigation buttons, right-click the Tool Bar area, and check ‘Navigation’ . Use Acrobat’s extensive search capabilities, such as the ‘Find’...
Introduction Panel Organization XY/MD Model Under this model, the NV9641 provides a tree-structured (or hierarchical) button layout. You can define a “tree” of buttons in such a way that each of the 16 LCD buttons (illuminated in various colors and having 1 to 3 lines of text) can either (1) execute a function or (2) select a subtree (i.e., present an entirely new set of functions at a different level in the tree).
NV9641 User’s Guide a “back” button if there are more sources than buttons. Pressing the ‘Forward’ button takes you to the next page of sources. Pressing the ‘Back’ button takes you to the previous page of sources. Some button states depend on context. Many buttons remain unlit when their functions are disabled.
Introduction Other NV9641 Functions “single-bus, ” “single-destination, ” or “button-per-source” mode — can be emulated in either X-Y mode or MD mode. The primary modes of operation are: • X-Y Mode — individual control of all router levels. Choose a destination, optionally choose desired breakaway levels, choose a source, and press ‘Take’...
Page 17
NV9641 User’s Guide • Hold breakaway levels. • System salvos. • Forced release of locked or protected devices. • Device selection using indexes or suffixes. The NV9641 provides the following additional features: • Multiple-level breakaways in X-Y mode. This lets you route multiple sources to the same destination on different levels.
NV9641 User’s Guide Initialization Before your system controller can communicate with an NV9641, you must give it a panel ID. Follow these steps for each NV9641 you are installing: 1 Power up the NV9641. Do not connect its Ethernet cable (or disconnect it if it is connected).
Page 22
Installation Testing that panel should be loaded and the buttons appropriate for that configuration should light in the colors appropriate for that configuration. If you continue to see “No Server, ” “Acquiring IP Address, ” or “Locating Network” on button 2, you might have a problem. Reboot everything and try again. ...
Configuration Chapter 4 provides configuration instructions for the NV9641. Summary Summary ................13 Adding a Panel to an NV9000 Configuration .
Configuration Adding a Panel to an NV9000 Configuration The Panel IP Configuration Utility is also available if you want the NV9641 to take a static IP address. Adding a Panel to an NV9000 Configuration You must create configurations for the NV9641 using NV9000-SE Utilities. We assume that you are familiar enough with NV9000-SE Utilities that you can understand the following material.
Page 25
NV9641 User’s Guide Click ‘Add Control Panel’ at the bottom of the configuration page. The ‘Add Control Panel’ page appears: Choose “NV9641” from the ‘Type’ field. Enter the panel ID you assigned to the panel (during initial power-up) in the ID field. Give a name to the panel in the name field and select a user. When you are creating a panel configuration you have 3 options.
Page 26
Configuration Adding a Panel to an NV9000 Configuration Return to the ‘Control Panels’ page to view your new entry. To edit an NV9641 configuration, either double-click its list entry or select the entry and then click ‘Edit Panel Configuration’: You will then see the panel configuration page for the selected NV9641. The following section of this guide discusses using the panel configuration page to configure an NV9641.
Configuration Regions of the Configuration Page Regions of the Configuration Page Above the ‘Revert to Saved’ and ‘Save’ buttons (always present) there are 5 main regions: • A graphic representation of the NV9641 panel. On the left are 16 LCD function buttons. Click on a button to assign a function to it. In some cases, you can click or double-click certain buttons to execute the button function.
NV9641 User’s Guide Configuration Tasks The person configuring an NV9641 panel will want to consider how best to use the button page tree under the XY/MD model or the list structure of the button page list under the paging model to support the devices and routers in the router control system at hand. The task is non-trivial.
Configuration Panel Options Panel Options The first panel option selects the behavioral model of the panel: XY/MD or paging. The panel options differ between the two models. The default model is XY/MD mode. Changing from one behavioral model to the other will erase the panel configuration. A confirmation warning appears when you make the change: Options under XY/MD Model This is the top part of the panel options section, as it appears at the right of a configuration...
Page 31
NV9641 User’s Guide Release Mode Normal Release This panel can release “locks” and “protects” set by the designated user (at this panel or any other panel). Force Release This panel can release locks and protects set by any user. Default None After a reset, the panel displays no destination device.
Configuration Options under XY/MD Model MD Data Automatic If a machine control (i.e., data) level is involved in a route, Routing Mode the system makes the route on the control level even if the control port is in use on the source or destination device. It breaks the previous control connection and then makes a new control connection for the route in progress.
Page 33
NV9641 User’s Guide A check in the box enables the option. Clearing the checkbox disables the option. The following items are the checkbox options under the panel options. • User-Programmable ID. Allows the panel ID to be changed locally at the control panel (in menu mode). •...
Configuration Options under the Paging Model • Flip-flop source to preset after take. Swaps the preset source and the currently routed source for this destination. • Enable force release. Allows operators to execute a force release. • Jump back after source selection. After you make a source selection, the panel reactivates the default button page.
NV9641 User’s Guide Drop-Down Menus These are the drop-down menu options under the paging model: Panel Behavior XY/MD Mode The panel configuration uses the XY/MD model. Model XY/MD supports a tree of button pages and allows the operator the choice of X-Y mode (multiple levels, single destination) or MD mode (all levels, multiple destinations) at any time.
Configuration Button Definitions • Source (Is) Master Default. Makes a control-level source the controlling device (or master device) by default. Otherwise, the destination is the master by default. (The option is specifically for use with NVISION series data routers.) “Source is master” is used for duplication, or broadcast routing, on the control level. “Destination is master”...
NV9641 User’s Guide devices in a category can change over time (as the configuration database changes); the NV9641 device list changes also. The number and names of categories can also change over time and the NV9641 will track those changes too. When a device list appears on the panel, the system lights the ‘up’...
Configuration Button Types active. (An exception to this is the LCD brightness submenu when the panel is in menu mode.) Some button types are never high-tally. Check box “Place this button on all local pages. ” When the operator presses a ‘Navi- gate’...
Page 39
NV9641 User’s Guide Type Paging Description Category Displays a category’s device list. When you assign a category button, two additional drop-down menus appear: ‘Src Category’ and ‘Dst Category’ . Choose a category from one of the category lists. When you choose a source category, the destination categories become inaccessible and vice versa: a category button must be either a source category or a destination category.
Page 40
Configuration Button Types Type Paging Description Destination Sets or removes a “protect” on the current destination device. The Protect protect can be removed only by the user that originally set the protect, or by a panel that has “Force Release” enabled. Note: a protect prevents others from routing to a destination;...
Page 41
NV9641 User’s Guide Type Paging Description Name Set The button toggles the panel between its default name set and the Toggle “system name” set. One or the other becomes the active name set. The button definition has no fields to configure. If the default name set is the system name set, the button would be a no-op.
Page 42
Configuration Button Types Type Paging Description Salvo Executes a salvo. When you assign a Salvo button, a drop-down list appears in which you select a system salvo. The ‘None’ entry is merely a placeholder. Do not choose ‘None’ . (You can generate salvo buttons automatically in the ‘Edit Navigation Button’...
Page 43
NV9641 User’s Guide Type Paging Description Source A source button selects a source. (Note that a quick source button selects a source and also performs an immediate take.) When you assign a source button, a drop-down menu appears: ‘Source Device’ . Choose a device from the list. The ‘None’...
Page 44
Configuration Button Types Type Paging Description Virtual Level In X-Y mode, this button causes the alphanumeric display to show Expand virtual levels at the lowest level of grouping (with the most detail). The button affects only virtual levels that have been grouped. See Level Grouping page The button has no effect in multi-destination mode.
NV9641 User’s Guide ‘Edit Navigation Button’ Dialog Navigation buttons, and their corresponding target pages, are available only under the XY/MD model. The ‘Edit Navigation Button’ dialog is therefore available only under the XY/MD model. During configuration, when you choose ‘Navigate’ for a selected button, NV9000-SE Utilities displays an ‘Edit Navigate Button’...
Page 46
Configuration ‘Edit Navigation Button’ Dialog • Jump to an existing page. This options does not create a new page in the button tree. The navigation button you are creating will cause the NV9641 to display the page you select in the associated drop down menu.
Page 47
NV9641 User’s Guide • Quick Source Devices Automatic fill using quick source buttons for source devices is the same as for source devices, except that quick source buttons are used. In the case of manual fill, blank quick source buttons are created. •...
Configuration Button Page Table Button Page Table The page table under the XY/MD models differs from the page table under the paging model. Under XY/MD, the page table represents a hierarchical (tree) structure of button pages. Under the paging model, the page table represents a list structure of button pages. XY/MD Model This page table lists the pages of the button page tree.
NV9641 User’s Guide During operation, panel operators will press navigation buttons, global navigation buttons, or category buttons to jump to other pages. Navigation buttons do not jump to global suffix pages or global navigation pages. Only global navigation buttons jump to global navigation pages; only category buttons jump to suffix pages.
Configuration Tally (GPIO) Window The ‘Links to Page Num(s)’ column lists, for any page, the other pages that refer to it. Under the paging model, only one such referring page exists and that is the predecessor in the list. The first page, named “Default, ” has no predecessor. Tally (GPIO) Window Below the tree window is the tally section of the configuration page.
NV9641 User’s Guide hold mode or normal mode, whichever is in effect at the moment. Normal mode is the default — unless you specify otherwise in the Panel Options. Behavior XY Mode When the panel is in X-Y mode, a set of selection buttons presents a set of virtual levels. The levels displayed correspond to the levels in the level set of a selected destination device.
Configuration Configuration MD Mode — Normal When the user selects an MD device, all selection buttons are mutually exclusive: when the operator presses one button, any others that were selected turn off. To perform MD takes, the operator alternately selects an MD device and then a source until all intended devices have been preset.
NV9641 User’s Guide On the configuration page, when there are more MD devices than selection buttons, the up and down buttons become active and you can scroll through the set of MD devices to assign them to selection buttons. (You can enable up to 512 MD devices, in multiples of 8. See the ‘Multidest Device Limit’ box under Panel Options on page 20.) You do not have to commit every selection button to...
Configuration Global Navigation navigation button if you need it. This example shows 14 quick sources, a selection button, and one navigation button: for “Status” Quick Source Buttons to other pages One part of the configuration is specifying a default destination in the panel options during configuration.
NV9641 User’s Guide Names After adding global navigation templates to your N9000 configuration, you will see them identified as such in the control panel list: Navigation Template Suffix Template The words “Navigate” and “Suffix” appear in the ‘Panel Type’ and ‘Configuration Name’ columns.
Configuration Referencing a Navigate Template When you check the option, an addition ‘Suffix Page’ field appears. Choose one of the suffix templates in the drop-down list. The suffix page appears in the panel configuration’s button page list: Suffix page The suffix page is a copy of the suffix template.
NV9641 User’s Guide Choose a navigate template in that field. The global navigation page and any of its subpages appears in the panel configuration’s button page list: Global navigation page(s) The global navigation pages are copies made from the navigate template. They are not the template or a link to the template.
Configuration Composing Navigate Templates Template Changes If you make a change to a suffix template and it is in use (you’ll see the entries in the list) you’ll probably want to click ‘Push changes to panel configs’ . When you do, the configuration software adjusts all NV9641 panel configurations to use the modified suffix template.
NV9641 User’s Guide Template Changes If you make a change to a navigate template and it is in use by one or more panel configurations, you will want to click ‘Push changes to panel configs’ . You can see the panel configurations in the list under ‘Panel References’: List of panel configuration pages that use this navigate...
Operation Modes of Operation Because the panel’s buttons can have arbitrary legends, a button’s legend might or might not indicate its function. Operators and configurers will have to communicate about the meaning of the buttons in the button tree. Physically, you will find •...
NV9641 User’s Guide Usually, only configurers need be concerned with setup mode. Setup Mode on page 73. • Salvo mode — pressing a salvo button and then a take button executes a salvo. The duration of a salvo is indeterminate. •...
Operation Button Legends The top line of text identifies the current source. If the current destination had a breakaway take, the sources will be different across the set of level buttons. If the destination does not include a particular level, that button will be dark, but it will show the level name, as is the case with AES 3/4 here.
NV9641 User’s Guide If a breakaway occurred (in X-Y mode) for a particular destination, the MD destination button shows the destination mnemonic in reverse-field. The reverse field lets you know that this destination has a CAM1 CAM1 breakaway take. The top line of text represents the source for VTR3 the breakaway on the primary level of the route.
Operation Level Grouping It is not possible to take different sources to the destination on the same level. For instance, you cannot take SD from two different sources. The outcome would be noise even if you could do it. (That is because routers are not mixers.) Level Grouping Virtual levels can be grouped.
Page 67
NV9641 User’s Guide • The panel displays a list of all devices in that category. If the list has more entries than will fit on the available buttons, you can scroll through multiple pages of devices using ‘Back’ and ‘Forward’ buttons to find the device you want. •...
Operation Category Selection Destination Lock (P) Preset Release Virtual Levels Contract Destination Protect Previous Source X-Y Display Forward Quick Source XY/MD Mode Free Source Salvo Here, the buttons that are available under the paging model are flagged with the letter “P. ” Not listed here are the up and down buttons.
NV9641 User’s Guide enter an index or suffixes of a device within the category. If you make a mistake, press the ‘Clear Preset’ button and try again. When you have finished entering an index or suffixes, press either the back button or the take button if present.
Operation Category Selection Default State This button returns the NV9641 panel to its most recent power-up state. You can consider this button an emergency button or a “soft reset” button. This button does not affect any routes. Only the panel itself is reset. The default button text is “Default State”...
NV9641 User’s Guide Destination Protect This button is a toggle that sets or clears a protect on the current destination device. The protect can be removed at the panel that originally set the protect, at any panel that has the same user ID, or by a forced release at any panel. ...
Operation Category Selection Hold The ‘Hold’ button is a toggle. Press it once to activate “hold” mode, press it again to deactivate “hold. ” The button is high-tally when hold mode is active and low-tally when it is not. You can activate or deactivate hold mode at any time during an MD selection or a breakaway selection in X-Y mode.
NV9641 User’s Guide Name Set Toggle An ‘Name Set Toggle’ button toggles the panel between its default name set and the “system name” set. Whichever name set you select becomes the “active” name set. ‘Name Set Toggle’ buttons are disabled while a category selection is in progress. ...
Operation Category Selection can release it if your panel has “forced release” enabled. (Note that you cannot lock or protect sources with the NV9641.) Press the ‘Preset Release’ button to release the source. The default button text is “Preset Release” but the button can have any legend. Previous Source This button presets the previously selected source for the current destination.
Page 75
NV9641 User’s Guide A button page that has selection buttons will have up to 8 of them. X-Y Mode When the panel is in X-Y mode, a selection button presents a virtual level that corresponds to the display index for the button and the preset source or destination device. Pressing selection buttons selects or unselects the levels associated with the buttons.
Operation Category Selection Source A source button selects a source. (Note that a quick source button selects a source and also performs an immediate take.) Quick source and source buttons are similar, except that the quick source performs a take. Be aware of which buttons are quick sources so you do not perform an accidental take.
NV9641 User’s Guide Virtual Level Expander In X-Y mode, this button causes the alphanumeric display to show virtual levels at the lowest level of grouping (with the most detail). The button affects only virtual levels that have been grouped. See Level Grouping on page 56.
Operation Takes Release To remove a lock or protect. Some control panels can lock or protect both sources and destinations. However, The NV9641 provides locks and protects for destinations only. A forced release is when the lock or protect is removed by someone other than the owner. A forced release can be performed: •...
NV9641 User’s Guide Name Sets NV9000-SE Utilities allows configurers to define multiple name sets. Each name set contains aliases (alternate names) for any and all devices in the NV9000 system. The aliases can appear in the displays of your panel. Further, your panel can have a ‘Name Set Toggle’...
Operation Data Routing In MD mode, with hold mode active, you can select multiple broadcast destinations with a single take. Implicit in the ‘Broadcast’ button is the “source is master” mode. It is not necessary to press ‘Source is Master’ repeatedly. The reason you must press ‘Source is Master’ the first time is that “broadcast mode”...
NV9641 User’s Guide If neither of the control ports for the source or destination are in use, the take occurs naturally without any further action required. Note that the ports will become “in use” after the take you are performing. Follow these steps to take the data level as a breakaway: 1 Select a destination.
Operation User User Press the ‘User’ button to view user data: USER USER USER ID USER ID EnvyUser EnvyUser O1 O1 EXIT EXIT The 2 buttons on the left tell you the user name and user ID as determined by the router control system.
NV9641 User’s Guide This illustration shows that high-tally green was changed to medium brightness and low- tally amber was also changed to medium brightness. If you make a change, press ‘Save’ to commit the change or press ‘Cancel’ to discard the change.
Page 84
Operation Setup Mode In the setup menu, press the ‘Panel Test Mode’ button. One button appears: PUSH PUSH TO TO TEST TEST Press the ‘Push to Test’ button repeatedly to execute the test. Each time you press the button, the panel illuminates all its LCD buttons in a single color, changing the color each time you press the button.
GPIO Output When the input transitions off or transitions on, the NV9641 notifies the router control system, which carries out the task defined for the input (if a task has been configured). During contact closure, a current of 1.2 mA flows. A maximum of 48 VDC can be applied to the tally input for less than 5 seconds without failure.
NV9641 User’s Guide The GPIO Section of the NV9641 Page SE’s NV9641 configuration page provides a GPIO section, below the tree window: Click on a button under ‘Outputs’ to configure one of the 4 tally outputs. Click on a button under ‘Inputs’ to configure one of the 8 tally inputs. ...
Page 88
GPIO Configuring Outputs Terms (i.e., operands) are generated by choosing entries in the other fields in this dialog and clicking ‘ADD’ . The example shows the following: Dest. Device: MON2 Dest. Level: Source Device: CAM1 Source Level: Choosing these items (and clicking ADD) produces the Boolean sub-expression: SD on CAM1 is switched to SD on MON2 In Figure 6-4, that sub-expression is ANDed with another sub-expression INPUT 3 OR INPUT 8...
NV9641 User’s Guide reconstruct the term in the appropriate entry fields, and click the ‘Change’ button to effect the change. Using the arrows is the only way to position between two items or at the end of the expression. You can double-click a term or an operator to select it directly. You can click ‘Check Syntax’...
GPIO GPIO Summary 3 Route the “previous source” switched by this panel to a destination, even if it is the same as the current source. If you choose this behavior, select a destination in the destination drop-down list. 4 Route a source to a destination. If you choose this behavior, select a source and a destination in the two drop-down lists.
Technical Details Chapter 7 provides electrical and mechanical specifications for the NV9641. Summary Power Specifications ..............81 NV9641 Specifications .
Technical Details NV9641 Specifications 2.39 [60.7] 5.24 [133.0] Indicator LED 1.62 [41.0] AC Input DC Output Fig. 7-1: The power output has Molex 4-pin plug. See Power Cord Retention page NV9641 Specifications NV9641 Physical Specifications Specification Detail Dimensions Height: 1.72 in (43.7 mm), fits EIA 1 RU (1.75 in or 44.5 mm), Width: 19.0 in (482.6 mm).
NV9641 User’s Guide Environmental Specifications NV9641 Environmental Specifications Specification Detail Operating temperature 0–40 ° C, ambient. Relative humidity 0 to 90%, non-condensing. Cooling No fan required. Defaults Initial Panel State Multi-destination mode or X-Y mode, selectable. Destination: the configured default. Buttons: high-tally is maximum brightness;...
Misc. Topics Power Cord Retention To apply a label to a button, pull the clear plastic cap from the button, insert the label in the cap, and replace the cap. The caps come off easily. No tools are required. We recommend that you not use adhesive.
NV9641 User’s Guide 6 Examine the strap though its path around the cord and power supply. Be sure that no slack exists and that it is tight the full length of the strap. If necessary, adjust and cinch it more tightly. Ordering Information These are the NV9641 components: PS0001...
Page 101
Glossary AES/EBU (Audio Engineering Society/European Broadcasting Union). AES and EBU are standards organizations. Breakaway A condition where a destination has multiple sources on different levels. Category A category represents a set of devices. (The concept of categories exists to make it easier to select devices at a control panel.) A category can contain sources, destinations, or devices that are both sources and destinations.
Page 102
Glossary one or more input ports. A destination is a device that is connected to one or more output ports. An example of such a device would be a monitor. A device can be both a source and destination. An example of such a device is a VTR. System The system administrator is the person responsible for installing, configuring, and administrator...
Page 103
Index Broadcast mode ......70 Broadcast routes ......69 Button Acquiring IP address (message) .
Page 110
Index User interface ....... 13 User’s guide, chapter structure ....1 User-programmable panel ID .
Page 111
Contact Us Grass Valley Technical Support For technical assistance, contact our international support center, at 1-800-547-8949 (US and Canada) or +1 530 478 4148. To obtain a local phone number for the support center nearest you, please consult the Contact Us section of Grass Valley’s website ( www.grassvalley.com An online form for e-mail contact is also available from the website.
Need help?
Do you have a question about the GRASS VALLEY NV9641 and is the answer not in the manual?
Questions and answers