1. Open the panel, remove the screw on
the wiring cover and then take down the
cover.
2. Make the power connection wire go
through the cable-cross hole at the
back of indoor unit and then pull it
out from the front side.
3. Remove the wire clip; connect the power connection wire to the wiring
terminal according to the color; tighten the screw and then fi x the power
connection wire with wire clip.
power
connection
wire
9K
N(1)
2
3
Blue
Black
Outdoor unit connection
12K, 17Κ, 21Κ
N(1)
2
3
Blue
Black
Brown
Outdoor unit connection
86
panel
cable-
cross
hole
Brown
Yellow-
green
Yellow-
green
screw
wiring cover