Toyotomi UTN-09AP User Manual

Toyotomi UTN-09AP User Manual

Wall mounted air conditioner inverter type condizionatore split
Hide thumbs Also See for UTN-09AP:

Advertisement

Οδηγίες Χρήσης
User's Manual
Manuale d'installazione ed uso
ΚΛΙΜΑΤΙΣΤΙΚΟ TOIXOY DC INVERTER
WALL MOUNTED AIR CONDITIONER INVERTER TYPE
CONDIZIONATORE SPLIT
ΜΟΝΤΕΛΑ / MODELS / MODELLI
UTN/UTG-09AP
UTN/UTG-12AP
Ευχαριστούμε για την επιλογή σας στα κλιματιστικά οικιακής χρήσης TOYOTOMI.
Πριν χρησιμοποιήσετε αυτή τη συσκευή, παρακαλούμε διαβάστε προσεκτικά αυτό το
εγχειρίδιο χρήσεως. Κρατήστε αυτό το εγχειρίδιο χρήσεως για μελλοντική αναφορά σε αυτό.
Thank you for your choice in TOYOTOMI Wall Mounted Air Conditioners.
Before using this product, be sure to read this Instruction Manual carefully to ensure proper
usage. Keep this manual in good shape for future reference.
Grazie per aver scelto un prodotto TOYOTOMI.
Per un corretto funzionamento, leggere attentamente questo manuale prima di usare il
condizionatore e conservarlo per una futura consultazione.

Advertisement

Table of Contents
loading

Summary of Contents for Toyotomi UTN-09AP

  • Page 1 Πριν χρησιμοποιήσετε αυτή τη συσκευή, παρακαλούμε διαβάστε προσεκτικά αυτό το εγχειρίδιο χρήσεως. Κρατήστε αυτό το εγχειρίδιο χρήσεως για μελλοντική αναφορά σε αυτό. Thank you for your choice in TOYOTOMI Wall Mounted Air Conditioners. Before using this product, be sure to read this Instruction Manual carefully to ensure proper usage.
  • Page 2: Table Of Contents

    CONTENTS THE REFRIGERANT ................59-60 PRECAUTIONS ..................61-64 PARTS NAME ..................65-66 BUTTONS ON THE REMOTE CONTROLLER ..........67 INTRODUCTION FOR BUTTONS OF REMOTE CONTROLLER ..68-71 REPLACEMENT OF BATERIES IN REMOTE CONTROLLER ....72 EMERGENCY OPERATION ..............72 CLEAN AND MAINTENANCE .............. 73-74 TROUBLE –...
  • Page 3: The Refrigerant

    DANGER: This symbol indicates a dangerous situation that if not avoided could lead to death or serious injury. WARNING: This symbol indicates a dangerous situation that if not avoided could lead to death or serious injury. ATTENTION: This symbol indicates a dangerous situation that if not avoided could lead to minor or moderate damage.
  • Page 4 Refrigerant R32: GWP 675 § To realize the function of the air conditioner unit, a special refrigerant circulates in the system. The used refrigerant is the fl uoride R32, which is specially cleaned. The refrigerant is fl ammable and inodorous. Furthermore, it can lead to explosion under certain conditions.
  • Page 5: Precautions

    PRECAUTIONS WARNING Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 6 shock or damage. Please contact your dealer when you need to repair air conditioner. DO NOT insert fi ngers or objects into air inlet or air outlet. It may cause personal injury or damage. DO NOT block air outlet or air inlet. It may cause malfunction. DO NOT spill water on the remote controller, otherwise the remote controller may be broken.
  • Page 7 and heating buckle function, it can protect the circuit-short and overload. Air Conditioner should be properly grounded. Incorrect grounding may cause electric shock. DO NOT use unqualifi ed power cord. Make sure the power supply matches with the requirement of air conditioner.
  • Page 8 a professional. If the length of power connection wire is insuffi cient please contact the supplier for a new one. Avoid extending the wire by yourself. For the air conditioner with plug the plug should be reachable after fi nishing installation. For the air conditioner without plug, an circuit break must be installed in the line.
  • Page 9: Parts Name

    Working temperature range Indoor Side DB/WB Outdoor Side DB/WB (ºC) (ºC) Maximum Cooling 32/23 43/26 Maximum Heating 27/- 24/18 NOTICE: The operating temperature range (outdoor temperature) for heat pump unit is -15 ºC ~ 43 ºC. PARTS NAME Air inlet Panel Filter aux button...
  • Page 10 OUTDOOR UNIT Air inlet Air outlet...
  • Page 11: Buttons On The Remote Controller

    BUTTONS ON THE REMOTE CONTROLLER On/Off button Mode button Fan button button Swing button Sleep button Temp button Turbo button button Timer button WiFi button Light button Temp. display type Set temp. Indoor ambient temp. Outdoor ambient temp. Turbo mode Set fan speed Send signal Auto mode...
  • Page 12: Introduction For Buttons Of Remote Controller

    INTRODUCTION FOR BUTTONS OF REMOTE CONTROLLER Note: q This is a general use remote controller, it could be used for the air conditioners with multifunction. For some functions, which the model does not have, if press the corresponding button on the remote controller that the unit will keep the original running status.
  • Page 13 turned off the unit. After energization, X-FAN OFF is defaulted. X-FAN is not available in AUTO, FAN or HEAT mode. This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould. •...
  • Page 14 8 TURBO button Press this button to activate / deactivate the Turbo function Under COOL or HEAT mode. button Press this button to achieve the on and off of healthy and scavenging functions in operation status. Press this button for the fi rst time to start scavenging function;...
  • Page 15 keypad. If the remote controller is locked, symbol « » is displayed. Press them again for 3 seconds to unlock the controller. Combination “MODE” and “ ” buttons. Change between Fahrenheit and centigrade At unit OFF, press ‘’MODE’’ and “ ” buttons simultaneously to switch between ℃...
  • Page 16: Replacement Of Bateries In Remote Controller

    REPLACEMENT OF BATERIES IN REMOTE CONTROLLER Signal sender 1 Press the back side of remote controller marked battery with and then push out the cover of battery box along the arrow direction. reinstall 2 Replace two 7# (AAA 1.5V) dry batteries, and remove make sure the position of “+”...
  • Page 17: Clean And Maintenance

    CLEAN AND MAINTENANCE WARNING § Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock. § DO NOT wash the air conditioner with water to avoid electric shock. § DO NOT use volatile liquid to clean the air conditioner. Clean surface of indoor unit When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth or wet cloth to wipe it.
  • Page 18 § DO NOT use fi re or hair dryer to dry the fi lter. This may cause deformation or fi re hazard. § DO NOT clean the healthy fi lters with water. These fi lters must be cleaned only with a vacuum cleaner or simply by shaking them on the balcony. Note: Basic points that needs to be checked before use in case you have not used for a long time the air conditioner.
  • Page 19: Trouble - Cause - Solution

    TROUBLE – CAUSE – SOLUTION Phenomenon Check for Solution Pull out the plug. Reinsert Whether it is interfered se- the plug after about 3 min- verely (such as static elec- utes, and then turn on the tricity, stable voltage)? unit again. Whether remote controller Signal receiving range is is within the signal receiv-...
  • Page 20 Phenomenon Check for Solution Power failure? Wait until power recovery. Is plug loose? Reinsert the plug. Air switch trips off or fuse Ask professional to re- is burnt out? place air switch or fuse. Ask professional to re- Wiring has malfunction? conditioner cannot place it.
  • Page 21 Phenomenon Check for Solution Whether there is interfer- Disconnect power, Air Conditioner suddenly ence, such as thunder, back power, and then turn turned on. wireless devices, etc.? on the unit again. During defrosting under Heating mode is turned heating mode, it may gen- Outdoor unit has vapor.
  • Page 22: Installation Dimension Diagram

    WARNING § When below phenomenon occurs, please turn off air conditioner and disconnect power immediately and then contact the dealer or qualifi ed professional for service. § Power cord is overheating or damaged. § There is abnormal sound during operation. §...
  • Page 23 Space to the ceiling at least 50cm Drainage pipe Tools for installation Level meter Screw driver Impact drill Drill head Pipe expander Torque wrench Open-end wrench Pipe cutter Leakage detector Vacuum pump Pressure meter Universal meter Inner hexagon spanner Measuring tape...
  • Page 24 Note: § Please contact the local agent for installation. § DO NOT use unqualifi ed power cord. Selection of installation location Basic requirement Installing the unit in the following places may cause malfunction. If it is unavoidable, please consult the local dealer. 1.
  • Page 25: Safety Precaution

    Outdoor unit 1. Select a location where the noise and outfl ow air emitted by the outdoor unit will not affect neighborhood. 2. The location should be well ventilated and dry, in which the outdoor unit will not be exposed directly to sunlight or strong wind. 3.
  • Page 26: Grounding Requirement

    Please notice that the unit is fi lled with fl ammable gas R32. Inappropriate treatment of the unit involves the risk of severe damages of people and material. Details to this refrigerant are found in chapter “refrigerant”. GROUNDING REQUIREMENT 1. The air conditioner is the fi rst class electric appliance. It must be properly grounding with specialized grounding device by a professional.
  • Page 27 of drill head should be same as the plastic expansion particle) and then fi ll the plastic expansion particles in the holes 3. Fix the wall-mounting frame on the wall with tapping screws and then check if the frame is fi rmly installed by pulling the frame. If the plastic expansion particle is loose, please drill another fi...
  • Page 28 Note: § indoor outdoor Pay attention to dust prevention and take relevant safety measures when opening the hole. Φ55/ § The plastic expansion particles are not provided 5–10° Φ70 and should be bought locally. Step four: Outlet pipe 1. The pipe can be led out in the direction of right, rear right, left or rear left.
  • Page 29 4. Wrap the indoor pipe and joint of connection pipe with insulating pipe, and then wrap it with tape. insulating pipe Step six: Install drain hose 1. Connect the drain hose to the outlet pipe of indoor unit. drain hose outlet pipe drain hose outlet pipe...
  • Page 30 panel screw 1. Open the panel, remove the screw on the wiring cover and then take down the cover. wiring cover 2. Make the power connection wire go through the cable-cross hole at the cable- back of indoor unit and then pull it cross out from the front side.
  • Page 31 Note: The wiring board is for reference only, please refer to the actual one. 4. Put wiring cover back and then tighten the screw. 5. Close the panel. Step eight: Bind up pipe 1. Bind up the connection pipe, power cord and drain hose with the band. indoor and outdoor indoor unit power cord...
  • Page 32: Installation Of Outdoor Unit

    4. Fix the wall pipe. 5. Check if the indoor unit is installed fi rmly and closed to the wall. indoor outdoor upper hook wall pipe sealing gum lower hook of wall-mounting frame Note: § Do not bend the drain hose too excessively in order to prevent blocking. INSTALLATION OF OUTDOOR UNIT Step one: Fix the support of outdoor unit (select it according to the actual installation situation)
  • Page 33 Step two: Install drain joint 1. Connect the outdoor drain joint into the hole on the chassis, as shown in the picture below. 2. Connect the drain hose into the drain vent. drain vent chassis drain hose outdoor drain joint Note: As for the shape of drainage joint, please refer to the current product.
  • Page 34 3. Pretightening the union nut with hand. pipe joint union nut 4. Tighten the union nut with torque wrench by referring to the sheet below. Hex nut Tightening diameter torque (Ν-m) 1/4’’ 15~20 3/8’’ 30~40 1/2’’ 45~55 5/8’’ 60~65 3/4’’ 70~75 Step fi...
  • Page 35 Note: The wiring board is for reference only. Please refer to the actual one. 2. Fix the power connection wire and signal control wire with wire clip (only for cooling and heating unit). Note: § After tightening the screw, pull the power cord slightly to check if it is fi rm. §...
  • Page 36: Vacuum Pumping

    The drain hose cannot be fl uctuant The drain hose cannot The water outlet cannot be fl uctuant be fl uctuant VACUUM PUMPING liquid valve 1. Remove the valve caps piezometer on the liquid valve and gas valve gas valve and the nut of valve cap refrigerant refrigerant charging vent.
  • Page 37: Operation Test

    OPERATION TEST Pipe expanding method Note: Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: A: Cut the pipe § Confi rm the pipe length according pipe to the distance of indoor unit and outdoor unit.
  • Page 38: Leakage Detection

    F: Inspection smooth surface § Check the quality of expanding port. If there is any blemish, expand the improper expanding port again according to the steps above. leaning crack the lenght damaged uneven is equal surface thickness LEAKAGE DETECTION 1. With leakage detector: Check if there is leakage with leakage detector.
  • Page 39: Configuration Of Connection Pipe

    Max length of Cooling Capacity connection pipe 5000 (BTU/h) (1465W) 7000 (BTU/h) (2051W) 9000 (BTU/h) (2637W) 12000 (BTU/h) (3516W) 18000 (BTU/h) (5274W) 24000 (BTU/h) (7032W) 28000 (BTU/h) (8204W) 36000 (BTU/h) (10548W) 42000 (BTU/h) (12306W) 48000 (BTU/h) (14064W) 4. The additional refrigerant oil and refrigerant charging required after prolonging connection pipe.
  • Page 40: Safety Operation Of Flammable Refrigerant

    Note: The additional refrigerant charging amount in Sheet 2 is recommended value, not compulsory. Safety operation of fl ammable refrigerant Qualifi cation requirement for installation and maintenance man § All the work men who are engaging in the refrigeration system should bear the valid certifi...
  • Page 41: Maintenance Notes

    Charge amount (kg) Minimum Floor location 34.3 37.8 41.5 45.4 49.4 53.6 room area Window mounted 11.2 12.4 13.6 16.3 17.8 19.3 Wall mounted Ceiling mounted MAINTENANCE NOTES § Check whether the maintenance area or the room area meet the requirement of the nameplate.
  • Page 42: Check After Installation

    FILLING THE REFRIGERANT § Use the refrigerant fi lling appliances specialized for R32. Make sure that different kinds of refrigerant will not contaminate with each other. § The refrigerant tank should be kept upright at the time of fi lling refrigerant. §...
  • Page 43 Items to be checked Possible malfunction It may cause malfunction or damaging Does the power follow the specifi cation? the parts. Is there any obstruction in the air inlet It may cause insuffi cient cooling or and outlet? heating capacity. The dust and sundries caused during It may cause malfunction or damaging installation are removed?
  • Page 44: Specialist's Manual

    connection pipe is not yet connected, air will be sucked in and cause pressure rise or compressor rupture, resulting in injury. 5. When installing the unit, make sure that connection pipe is securely connected before the compressor starts running. If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause pressure rise or compressor rupture, resulting injury.
  • Page 45 shall also take into account the effects of aging or continual vibration from sources such as compressors or fans. • Detection of fl ammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked fl...
  • Page 46 j) When the cylinders have been fi lled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off. k) Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
  • Page 47 Αποκομιδή Παλαιού Ηλεκτρικού & Ηλεκτρονικού Εξοπλισμού (Ισχύει στην Ευρωπαϊκή Ένωση και άλλες Ευρωπαϊκές χώρες με συστήματα επιλεκτικής συλλογής απορριμμάτων). Το σύμβολο αυτό επάνω στο προϊόν ή στη συσκευασία του σημαίνει ότι το προ- ϊόν δεν πρέπει να πεταχτεί μαζί με τα οικιακά απορρίμματα αλλά πρέπει...
  • Page 48 Δήλωση Συμμόρφωσης έχει χορηγηθεί στον κατασκευαστή και εί- ναι στη διάθεση των αρμοδίων αρχών εποπτείας της αγοράς. Certifi cate of compliance CE TOYOTOMI CO., LTD declares that this product complies with the general requirements pursuant to the following European Directives: LVD: 2014/35/EU...
  • Page 49 ΣΗΜΕΙΩΣΕΙΣ...
  • Page 50 NOTES...
  • Page 51 It is prohibited to reprint or reproduction of all or part of this manual in any manner without written permission of TOYOTOMI CO., LTD È vietato ristampare o riprodurre tutto o parte di questo manuale in qualsiasi modo senza il permesso scritto di TOYOTOMI ITALIA S.R.L. ΕΠΙΣΗΜΗ ΑΝΤΙΠΡΟΣΩΠΕΙΑ ΕΛΛΑΔΑΣ Γ.Ε.ΔΗΜΗΤΡΙΟΥ Α.Ε.Ε.

This manual is also suitable for:

Utg-09apUtn-12apUtg-12ap

Table of Contents