A
PPS
QUADRATURE OR SIMPLE COUNTERS
•
Two Quadrature counters.
Counters are 26-bits wide. Maximum count 67,108,863 or ±33,554,431
•
Configurable line resolution 1, 2, 4. See diagram below for additional detail
•
•
Dedicated RESET pins
Raw counter value can be converted to any unit (distance, speed, etc.) using
•
Counter values can be used to control "XY Measurement app" or "Reticle app"
•
Interface compatible with Mechanical, Hall effect & Optical rotary encoders
•
The counters can be configured as Quadrature or Simple counters.
Terminal Block (J52-J53) Pins
DIN1
DIN2
DIN3
DIN4
DIN5
DIN6
X1:
1
1
1
1
X2:
1
1
2
2
X4:
1
2
3
4
As Quadrature Counters
RESET for Counter 1.
RESET for Counter 2
Quadrature Counter 1 inputs
Quadrature Counter 2 inputs
_ = ∗ _ +
2
2
2
2
3
3
3
3
3
4
4
5
5
6
5
6
7
8
9
10
11
As Simple Counters
RESET for Counter 1
RESET for Counter 2
Simple Counter 1 input
-
Simple Counter 2 input
-
30
3
4
6
7
12
13