Summary of Contents for motortronics VMX-Synergy Plus VMX-SGY-I-17

  • Page 2 équipement. Short Circuit Motortronics soft starts are not short circuit proof. After severe overload or short circuit, the operation of the soft start should be fully tested by an authorized service agent.
  • Page 3 Safety • VMX-Synergy Plus™ soft starts contain dangerous voltages when connected to the mains supply. Only qualified personnel that have been completely trained and authorized, should carry out installation, operation and maintenance of this equipment. • Les démarreurs progressifs VMX-Synergy Plus ™ contiennent des tensions dangereuses, lorsqu’ils sont connectés à...
  • Page 4: Model Number Description

    Model Number Description It is essential to check the VMX-Synergy Plus nameplate and make sure that the soft starter is properly sized for your AC motor. VMX-SGY-I-17-6-XX-XX Option Non-critical customer options (may be blank) Control supply U 01 – U = 24Vdc, 110VAC or 230VAC 02 –...
  • Page 5 Environment - Installation VMX-SGY-I-17 to VMX-SGY-I-100 (Size 1) Dimensions VMX-SGY-I-17 to VMX-SGY-I-29 Weight 3.9 kg (8.6 lbs) VMX-SGY-I-35 to VMX-SGY-I-100 Weight 4.2 kg (9.26 lbs) VMX-SGY-I-132 to VMX-SGY-I-195 (Size 2) Dimensions VMX-SGY-I-132 Weight 6.7 kg (14.78 lbs) VMX-SGY-I-160 to VMX-SGY-I-195 Weight 7.0 kg (15.44 lbs)
  • Page 6 Environment - Installation VMX-SGY-I-242 to VMX-SGY-I-361 (Size 3) Dimensions VMX-SGY-I-242 to VMX-SGY-I-361 Weight 17.0 kg (37.5 lbs) VMX-SGY-I-430 to VMX-SGY-I-500 (Size 3) Dimensions VMX-SGY-I-430 to VMX-SGY-I-500 Weight 22 kg (48.5 lbs)
  • Page 7 Environment - Installation Enclosure Internal Clearances Air Flow Model inch inch inch VMX-SGY-I-17 to VMX-SGY-I-100 0.98 2.95 0.98 VMX-SGY-I-132 to VMX-SGY-I-195 1.57 3.93 0.98 VMX-SGY-I-242 to VMX-SGY-I-500 2.36 4.92 0,98 Conductor size and torque requirements Terminal Models Conductor Size Torque Metric Imperial Ib-in...
  • Page 8 Environment - Installation Enclosure Ventilation When installing a VMX-Synergy Plus™ into an enclosure, ventilation must be provided if the heat output of the unit is greater than the cabinet will dissipate. Use the following formula to determine the fan requirement. An allowance has been incorporated into the formula so that the figure for Q is the air delivery in the fan supplier’s data.
  • Page 9 Terminal Designations and Wiring Connection...
  • Page 10: Terminal Description

    Terminal Description Terminal Description Programmable Default Rating Notes Name 0V dc Control Supply See Table 1, Us 24V dc Signal ground Analog Output 0-10V or 4-20mA ACOM Analog Common Analog Input 0-10V or 4-20mA None D2-2I Digital Input 4 - Group 2 See Table 1, Uc Reset D2-1I...
  • Page 11: Wiring Connection

    Wiring Connection In Line In Delta Terml 2/T1 4/T2 6/T3 K1 – Main contactor or K1 – Main contactor and 1/L1 Circuit breaker isolation and protection switch gear and protection switch gear 3/L2 (provided by customer) (provided by customer) 5/L3 For suitable short For wire size and In Delta For this configuration applying...
  • Page 12 Wiring Connection 3 Wire Control Diagram 3 Wire Control Diagram 110/230Vac control supply (U 24Vdc control supply (U and digital input (U ) programming. and digital input (U ) programming. (VMX-SGY-I-17 to VMX-SGY-I-361) EMERGENCY STOP EMERGENCY STOP 110/230VAC 24VDC STOP STOP (OPTIONAL) (OPTIONAL)
  • Page 13 Programming Screen 1a on 1 Power On only. Subsequent use will show 1b OL = 0 = 0A P = 0...
  • Page 14: Rating Table

    Rating Table Minimum current ratings based on typical rated operation currents of motors for the corresponding rated operational powers Current rating optimized for kW@600V & hp@550-600V - Ref IEC 60947-4-1 Table G.1 where applicable. Size 1,2 and 3 Type 220- 440- 550- 230V...
  • Page 15: Technical Information

    Technical Information Motor overload 'cold' trip curves (20°C ambient) 1000 Multiple of Motor FLA Class10 Class20 Class30 Fig 1: Trip curves Note: When the overload has tripped, there is a forced cooling time to allow the overload to recover before the next start. The ‘warm’ trip times are 50 of the ‘cold’...
  • Page 16 Technical Information & Standards Rated operational voltages 200VAC to 600Vac Rated operational currents See Rating Table VMX-SGY-I-17 to VMX-SGY-I-361 Ie: AC-53a:3.5-17:90-5 Rating index VMX-SGY-I-430 to VMX-SGY-I-500 Ie: AC-53a:3.5-17:90-3 Rated 50 - 60Hz ± 5Hz frequency/frequencies Rated duty Uninterrupted. Form designation Form 1, Internally Bypassed Rated insulation voltage 600V...
  • Page 17 Altitude & Short Circuit Protection -20°C (-4°F) to 50°C (122°F). Above 50°C (122°F) de-rate linearly by 4 % of VMX- Synergy Plus Ie per °C to a maximum of 60°C (140°F). Altitude above sea level 1000m (3281ft). Above 1000m (3281ft) de rate by 1% of VMX-Synergy Plus Ie per 100m (328ft) to a maximum altitude of 2000m (6562ft).
  • Page 18: Sizing Guide

    Sizing Guide In-Line Connection Size 1 and 2 Trip Class Trip Class Trip Class : AC-53a: : AC-53a: : AC-53a: 440- 230V 400V 500V A 200V 208V 220-240V 550-600V 3.5-17: 90-5 4-19: 90-5 4-29: 90-5 480V VMX- VMX- VMX- SGY-I-17 SGY-I-22 SGY-I-29 SGY-I-22...
  • Page 19 Sizing Guide (Continued) In-Delta Connection Size 1 and 2 Trip Class Trip Class 20 Trip Class 30 : AC-53a: : AC-53a: : AC-53a: 220- 440- 550- 3.5-17: 90- 4-19: 90-5 4-29: 90-5 240V 480V 600V VMX- VMX- VMX- 15 18.5 29 SGY-I-17 SGY-I-22 SGY-I-29...
  • Page 20 Electric current, Danger to life! Livsfara genom elektrisk ström! Only skilled or instructed persons may carry out the operations. Endast utbildade elektriker och personer som undervisats i elektroteknik får utföra de arbeten som beskrivs nedan. Lebensgefahr durch Strom! Hengenvaarallinen jännite! Nur Elektrofachkräfte und elektrotechnisch unterwiesene Personen dürfen die Vain pätevät sähköasentajat ja opastusta saaneet henkilöt saavat suorittaa im Folgenden beschriebenen Arbeiten ausführen.
  • Page 21 Notes...
  • Page 22 Notes...
  • Page 23 Notes...