2. Mount the coupling half on the spindle.
The radial/axial runout deviation between the coupling and the spindle axis will determine
how smoothly the spindle will run when the coupling half is mounted.
Observe the specified tolerances.
3. Balance the complete assembly (spindle with mounted coupling half).
Balance the complete assembly, that is, spindle with the mounted coupling half, on a
suitable fixture.
Residual imbalance complies with G1.
1PH1 main motors
Equipment Manual, 09/2021, A5E51077676A-AA
5.5 Installation as a direct drive for spindles
Mounting the motor
61