Figure 2.10
2.3

Connecting the Failsafe Alarm Relay

The failsafe relay can be configured to latch based on alarm conditions. The NO
(Normally Open) contact is closed when the unit is powered and there are no active
alarms. If the device is not powered or if an active alarm is configured, the relay
opens the NO contact and closes the NC (Normally Closed) contact.
Note
Control of the failsafe relay output is configurable through RUGGEDCOM RS1600T .
One common application for this relay is to signal an alarm if a power failure
occurs. For more information, refer to the RUGGEDCOM RS1600T User Guide for the
RUGGEDCOM RS1600T.
The following shows the proper relay connections.
1
2
3
Figure 2.11
RUGGEDCOM RS1600T
Installation Manual, 01/2021, C79000-G8976-1015-03
Dual AC/DC Power Supply
1
2
3
Normally Closed Terminal
Common Terminal
Normally Open Terminal
Failsafe Alarm Relay Wiring
2.3 Connecting the Failsafe Alarm Relay
Installing Device
15