Tpm Power 320 V - Ratio - Wittenstein TPM+ power Quick Start Manual

Hide thumbs Also See for TPM+ power:
Table of Contents

Advertisement

+
TPM
power
+
5.6 TPM
power 320 V – Ratio 4 – 35
Code
Beschreibung
S-0-0141
Motor type
P-0-4014
Type of construction of motor
P-0-0001
Switching frequency of the power stage
P-0-0018
Number of pole pairs
P-0-0051
Torque/force constant
P-0-0074
Encoder type 1 Resolver
Encoder type 1 EnDat
Encoder type 1 Hiperface
1
P-0-0109
Torque/force peak limit
P-0-0508
Commutation offset Resolver
Commutation offset EnDat
Commutation offset Hiperface
P-0-0510
Rotor inertia
P-0-4016
Direct-axis inductance of motor
P-0-4017
Quadrature-axis inductance of motor
P-0-4048
Stator resistance
S-0-0043
Velocity polarity parameter Resolver
Velocity polarity parameter EnDat
Velocity polarity parameter Hiperface
S-0-0055
Postion polarities Resolver
Postion polarities EnDat
Postion polarities Hiperface
Torque/force polarity parameter
S-0-0085
Resolver
Torque/force polarity parameter EnDat
Torque/force polarity parameter
Hiperface
1
S-0-0092
Bipolar torque/force limit value
S-0-0106
Current loop p. gain 1
S-0-0107
Current loop integral action time 1
S-0-0109
Motor peak current
S-0-0111
Motor current at standstill
S-0-0113
Maximum motor speed
S-0-0116
Feedback 1 resolution Resolver
Feedback 1 resolution EnDat
Feedback 1 resolution Hiperface
S-0-0201
Motor warning temperature
S-0-0204
Motor shutdown temperature
S-0-0100
Velocity loop proportional gain
S-0-0101
Velocity loop integral action time
P-0-0004
Velocity loop smooth. time constant
2
P-0-0525
Holding brake control word
S-0-0206
Drive on delay time
S-0-0207
Drive off delay time
P-0-0540
Torque of holding brake
1
Subject to static and dynamic loads as well as the lambda factor the max. acceleration motor current has to be
reduced. We recommend a detailed calculation with Cymex.
2
For actuators without brake P-0-0525 has to be set to 0.
Seite en-10
Revision: 02
Einheit
TPMP004S TPMP010S TPMP025S
-
TPMP004S TPMP010S TPMP025S
-
0
kHz
8
-
4
Nm/Aeff
0,56
0,56
-
10
-
8
-
4
%
333
314
-
512
512
-
Commutation offset stored in encoder
-
Commutation offset stored in encoder
kgm²
See Chapter 5.8
mH
3,66
1,00
mH
3,66
1,00
Ohm
7,10
0,73
-
0111
0111
-
0000
0000
-
0000
0000
-
1111
1111
-
0000
0000
-
0000
0000
-
0111
0111
-
0000
0000
-
0000
0000
%
333
314
V/A
19,35
5,28
ms
1,4
3,6
Aeff
9,00
29,40
Aeff
2,70
9,35
1/min
6000
6000
-
1
-
512
512
-
128
128
° C
130
130
° C
145
145
As/rad
0,05
0,05
ms
10
µs
250
250
-
100
100
ms
12
ms
6
Nm
1,1
4,5
4091-D021074
Quick Startup Guide
0
0
8
8
6
6
0,58
10
10
8
8
4
4
295
512
0,50
0,50
0,13
0111
0000
0000
1111
0000
0000
0111
0000
0000
295
2,65
10,3
70,00
23,73
6000
1
1
512
128
130
145
0,1
10
10
250
100
30
40
20
20
13
Release: 14.04.2010

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TPM+ power and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents