6. Specifications

Operating temperature:
Storage temperature:
Probe length:
Probe diameter:
Weight with 5 m cable:
Housing:
Filter:
Power consumption:
Supply voltage (using Campbell
Scientific cable):
Start-up time:
Maximum cable length:
Analog outputs
Offset at 0 V:
Deviation from digital signal:
Compliance:

6.1 Temperature measurement

Sensor:
Measurement range:
Output signal range:
Accuracy at 23 °C:
Long term stability:
–40 to 60 °C
–40 to 80 °C
160 mm (6.3 in), 172 mm (6.77 in) including connector
21 mm (0.83 in)
290 g (10.2 oz)
Plastic material / IP65
30 µm pore size, stainless steel mesh
<1.2 mA at 12 V
7 to 30 VDC (12 VDC recommended)
2 s typical
300 m (1000 ft) with 12 V power
±3 mV (maximum)
< ±1 mV (0.1 °C, 0.1% RH)
View the EU Declaration of Conformity at
www.campbellsci.com/ee181-l
Pt1000 Class A
–40 to 60 °C
0 to 1.0 V
±0.2 °C
<0.1 °C/year
EE181 Temperature and Relative Humidity Probe