Function
10-30 V supply
0 V supply
Track A
Track A inverse
Track B
Track B inverse
Track 0
Track 0 inverse
Cable shield
1)
Recommended, DI can be freely selected

Table 10: Colour and contact assignments for NORD TTL / HTL incremental encoders

Information
Encoder signal faults
Wires that are not required (e.g. Track A inverse / B inverse) must be insulated. Otherwise, if these
wires come into contact with each other or the cable shield, short-circuits may occur, which can cause
encoder signal problems or destruction of the encoder.
Information
Incremental encoder data sheet
If the equipment deviates from the standard equipment (Type 5820.0H40, 10-30V encoder,
TTL/RS422 or encoder type 5820.0H30, 10 ... 30 V encoder, HTL) for the motors, please note the
accompanying data sheet or consult your supplier.
BU 0600 en-3221
Cable colours for
incremental
encoders
Brown / green
X13: 43
White / green
X13: 40
Brown
X13: 51
Green
X13: 52
Grey
X13: 53
Pink
X13: 54
Red
X11: 25
Black
Connect to a large area of the frequency inverter housing or shielding bracket
2 Assembly and installation
Signal type TTL
(24 V)
GND
A+
A-
B+
B-
1)
DI5
-
-
Signal type HTL
X11: 43
(24 V)
X11: 40
GND
X11: 23
DI3
-
-
X11: 24
DI4
-
-
1)
X11: 25
DI5
-
-