Page 1
User Manual Commercial School Milk Cooler User’s Manual 09/2017 Commercial School Milk Coolers: MC34HC, 178 MC49HC, 178 MC58HC Please read the manual thoroughly prior to equipment set-up, operation and maintenance. - 1 -...
Page 2
User Manual Warning DANGER – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY TRAINED SERVICE PERSONNEL. DO NOT PUNCTURE REFRIGERANT TUBING. DANGER – RISQUE DE FEU OU D’EXPLOSION. LE FRIGORIGÈNE EST INFLAMMABLE. CONFIER LES RÉPARATIONS À UN TECHNICIEN SPÉCIALISÉ. NE PAS PERFORER LA TUBULURE CONTENANT LE FRIGORIGENE.
Page 3
User Manual Exploded Parts Diagram - 3 -...
Page 4
User Manual Item Parts Name CSP Part # Front door for MC34 Front door for MC49 Compressor 17810635 Front door for MC58 Power cord protector 20 Transformer Power cord protector 33 Door connector 178HINGMC Caster 17819301 Top lid for MC34 Caster with brake 17816412 Top lid for MC49...
This equipment has been inspected and tested in the Avantco Refrigeration. Facility and has been crated in accordance with transportation rules and guidelines. Manufacturer is not responsible for freight loss or damage.
User Manual General Operation The milk coolers are cooled entirely by convection as a result of copper coils completely encircling the perimeter of the storage compartment. During the refrigeration process, heat is removed through the evaporator tubing and expelled through the condensing unit. It is important that the flow of air through the side louvers is not restricted in order to ensure the condensing unit operates properly.
User Manual Running a Manual Defrost Cycle Units are pre-programmed to run automatic defrost cycles at preset intervals. However, if you would like to run a manual defrost cycle at any time, please follow the steps below: 1. Press the defrost button (snowflake symbol and down arrow) for approximately 3 seconds. 2.
User Manual Troubleshooting Compressor Will Not Start, No Hum Service cord unplugged Plug in service cord Fuse blown or removed Determine reasons and correct Control stuck open Repair or replace Wiring incorrect Check wiring against the diagram Compressor Will Not Start, Hums but Trips Overload Protector Improperly wired Check against the wiring diagram...
5 Year Compressor Warranty In addition to the 1 year parts and labor warranty above, Avantco Refrigeration warrants the compressor on select units to be free of defects in material and workmanship for a period of 5 years from the date of delivery.