Avantco 178MC34HC User Manual

Avantco 178MC34HC User Manual

School milk cooler
Hide thumbs Also See for 178MC34HC:

Advertisement

School Milk Cooler
Models:
#178MC34HC 34" Commercial School Milk Cooler
#178MC49HC 49" Commercial School Milk Cooler
#178MC58HC
58" Commercial School Milk Cooler
Note:
Please read the manual thoroughly prior to equipment set-up, operation, and maintenance.
www.AvantcoRefrigeration.com
User Manual
02/2023
178MC34HC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 178MC34HC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Avantco 178MC34HC

  • Page 1 User Manual 02/2023 178MC34HC School Milk Cooler Models: #178MC34HC 34" Commercial School Milk Cooler #178MC49HC 49" Commercial School Milk Cooler #178MC58HC 58" Commercial School Milk Cooler Note: Please read the manual thoroughly prior to equipment set-up, operation, and maintenance. www.AvantcoRefrigeration.com...
  • Page 2: Table Of Contents

    User Manual Commercial School Milk Coolers Table of Contents Safety ..............................3 Cabinet Location Guidelines ...................... 4 Inspection ............................5 Installation ............................5 Safety Warnings ..........................6 Operation / Maintenace ....................... 7 Troubleshooting ..........................9 www.AvantcoRefrigeration.com...
  • Page 3: Safety

    User Manual Commercial School Milk Coolers Safety Warning DANGER – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY TRAINED SERVICE PERSONNEL. DO NOT PUNCTURE REFRIGERANT TUBING. PELIGRO – RIESGO DE INCENDIO O EXPLOSION. REFRIGERANTE INFLAMABLE UTILIZADO. PARASER REPARADO SOLAMENTE POR PERSONAL DE SERVICIO CALIFICADO.
  • Page 4: Cabinet Location Guidelines

    User Manual Commercial School Milk Coolers Safety This unit is intended for use in a temperature-controlled environment less than 75 degrees Fahrenheit and 60% relative humidity. Malfunction due to improper conditions is not covered under warranty. IMPORTANT – Please Read Before Installation: •...
  • Page 5: Inspection

    If any damage is found, it should be reported to the carrier at once, and a claim should be filed with the carrier. This equipment has been inspected and tested in the Avantco Refrigeration facility and has been crated in accordance with transportation rules and guidelines. Manufacturer is not responsible for freight loss or damage.
  • Page 6: Safety Warnings

    User Manual Commercial School Milk Coolers Adjusting the Temperature Your new milk cooler is already factory-set to run at optimum temperatures for food safety and should require no adjustments. Refrigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a maximum temperature of 40 degrees Fahrenheit.
  • Page 7: Operation / Maintenace

    User Manual Commercial School Milk Coolers PROPER GROUNDING REQUIRED To minimize shock and fire hazards, make sure that the unit is properly grounded. WARNING • Do not attempt to remove or repair any component unless instructed by factory. • Make sure that the unit is not resting on or against the electrical cord and plug. •...
  • Page 8 User Manual Commercial School Milk Coolers Condenser Coil Cleaning Instructions: A dusty condenser may lead to high energy consumption, less cooling effectiveness, and compressor damage. The condenser coil is located at the bottom behind the panel. 1. Disconnect the electrical power from the unit. 2.
  • Page 9: Troubleshooting

    User Manual Commercial School Milk Coolers Troubleshooting Problem Possible Solution • Check if the unit is plugged into a proper outlet with power Unit Will not Turn on • Check if contoller's LED screen lights up • Call service agency •...