Veris Industries E50H2A Installation Manual page 20

Compact power and energy meters with bacnet ms/tp support
Table of Contents

Advertisement

Installation Guide
Power Monitoring
E50H2A, E50H5A
BACnet
Programming
Information
(cont.)
Device Object
Property
Object_Identifier
Object_Type
Object_Name
Vendor_Name
Vendor_Identifier
Model_Name
Firmware_Revision
Application_Software_ Version
Location
Description
Protocol_Version
Protocol_Revsion
Local_Date
Local_Time
Segmentation_Supported
Max_Master
Max_Info_Frames
Max_APDU_Length_Accepted
APDU_Timeout
Number_of_APDU_Retries
System_Status
Protocol_Sevices_Supported
Protocol_Object_Types_Supported
ZL0117-0D
Page 20 of 28
Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Aerospond, Veris, and the Veris 'V' logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.
Legend
R/W
R=read only; R/W=read or write
NV
Value is stored in non-volatile memory. The value are still available if the meter experiences a power loss and reset.
Units
Lists the physical units that a register holds.
R/W
NV
Value Returned
R/W
NV
Device<n>
R
NV
Device (8)
R
NV
Veris E50 Series Energy Meter - S/N: <serial
number>
R
NV
Veris Industries, LLC
R
NV
133
R
NV
E50HxA Energy Meter
R
NV
<Current Revision #>
R
NV
<Current version #>
R/W
NV
<Location>
R
NV
Veris E50HxA DIN-Rail Energy Meter S/N:
<serial number>
R
NV
1
R
NV
4
R
Date
R
Time
R
NV
NO_SEGMENTATION (3)
R/W
NV
1-127 (Factory Default is 127)
R
NV
1
R
NV
480
R
NV
60000
R
NV
0
R
NV
Operational (0)
R
NV
0b0000000000001011010000000000000
011110000
R
NV
0b1011000010000000000010000000000
©2013 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com
Other companies' trademarks are hereby acknowledged to belong to their respective owners.
Additional information
n is the 7 digit ID # set in the ID1 & ID2 setup screens on the meter. The BACnet Device
ID is a decimal number from 1 to 4,193,999 that can be entered or viewed on the user
screens or through this property. The default value set at the factory is a psuedo-
random number from 1,000,000 to 3,097,151 to reduce the likelihood of conflicts if
multiple units are installed using their default IDs.
"xyyy".
This is the BACnet processor firmware version in the format <xyyy>, with an implied
decimal point between the first two digits (x.yyy)
"RS= xyyy, OS=xyyy, BACnet Gateway=xyyy"
The format <xyyy> has an implied decimal point between the first two digits (x.yyy)
Limted to 64 Characters - Default value is "Installed location not yet identified"
BACnet Protocol Version 1
BACnet Protocol Revision 4
Set via BACnet Time Synchronization only - reverts to Jan 1, 2000 if control power drops
Set via BACnet Time Synchronization only - reverts to 12:00:00 AM if control power
drops
Segmentation is not supported
Highest possible MAC Address for Master nodes on the local MS/TP network
Maximum number of information frames allowed before passing the MS/TP token
TM
08131

Advertisement

Table of Contents
loading

This manual is also suitable for:

E50h5a

Table of Contents