UNIT OPERATION
RE-LOADING DRY ICE
Always wear gloves to protect hands from exposure to cryogenic
temperatures and sharp blade surfaces.
1. Move the applicator mode select switch to the OFF (O) position.
2. Move the pusher plate back to the end of the trough away, from shaver wheel.
3. Remove excess dry ice and wipe out excess moisture.
4. Place dry ice into the trough, against the rotary knives.
5. Close the fill lid.
6. Press green reset power on/reset button
turns on.
7. Move the applicator mode select switch to the air + dry ice position (II).
8. Squeeze the blast applicator trigger to blast.
SHUT DOWN
Always wear gloves to protect hands from exposure to cryogenic
temperatures and sharp blade surfaces.
Always disconnect electric cables and hoses before transporting the unit.
To shut down the i
3
1. Release trigger to stop blasting.
2. Move the blast applicator mode select switch to the OFF (O) position.
3. Push in the blue trigger disable button. Turn the main power circuit breaker to
the OFF (O) position to shut off the power.
4. Open the fill lid and remove remaining dry ice from the trough.
5. Close the fill lid.
6. Shut off the compressed air supply.
7. Open the bleed valve to evacuate all remaining pressure.
8. When the air hose is fully depressurized, disconnect all electric cables and hoses.