Safety Notes; Technical Data; Maintenance; Replacement Parts - Grohe BAU COSMOPOLITAN E 36 466 Manual

Table of Contents

Advertisement

USA

Safety notes

Prevent danger resulting from damaged voltage
supply cables.
If damaged, the voltage supply cable must be replaced
by the manufacturer or his customer service
department or an equally qualified person.
• Installation is only possible in frost-free rooms.
• The plug-in voltage supply is only suitable for indoor use.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
• The voltage supply must be separately switchable.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and could lead to injuries.

Technical data

Fitting with switched-mode power supply:
• Voltage supply:
• Power consumption:
Fitting with battery:
• Voltage supply:
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (0 - 19 s adjustable):
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (7 - 20 cm adjustable):
Thermal disinfection possible.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
Undesired water
• Sensor system detection zone set too high
flow
• Automatic flushing activated
• Solenoid valve defective
Flow rate too low
• Flow control dirty
• Inlet adapter dirty
Mixer lever
• Mixer spindle defective
difficult to turn
#
100-240 V AC 50-60 Hz/6.75 V DC
6V lithium battery type CR-P2
- Battery discharged
(indicator lamp lights up continuously)
- Power supply unit defective
for local conditions
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Avoid major pressure differences between hot and cold water
supply!

Maintenance

Batteries which are almost discharged are displayed
by a flashing indicator lamp in the sensor system.

Replacement parts

See page 26 (* = special accessories)
2.4 W
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
57 s

Disposal notes

1 s
This category of device does not belong in the
domestic waste, but must be disposed of
12 cm
separately in accordance with the relevant
national regulations.
Remedy
- Replace solenoid valve
- Check plug-in connector electronics and solenoid
valve
- Replace battery
- Replace power supply unit
- Reduce range using remote control (special
accessory, prod. no.: 36 407) / app
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean or replace flow control
- Clean or replace inlet adapter
- Replace mixer lever / spindle
A
2
2500 V
100 °C
I
22