F-RA-001-5R0 For Safe Use ◆ Introduction This product generates high voltage and energy. In order to use the product safely and prior to using the product, please read the instruction manual to the end before use in order to use the product safely, because there is a danger of death or serious injury due to electric shock.
Page 3
F-RA-001-5R0 WARNING ◆ Understand the risk. Products generate high voltage and energy. An electrician or equivalent knowledge must read the instruction manual to the end and familiarize yourself with the proper use and danger of the product. If you want the product to be handled by another person, limit it to those with knowledge of electricity, and have people who are familiar with correct use and danger of the product conduct education and training before handling it, or handle the product under the supervision of those who are familiar with the proper use and danger of the product.
Page 4
F-RA-001-5R0 WARNING ◆ Designed for indoor use Use the product indoors. Do not use it outdoors or indoors where there is a possibility of water leakage, flooding, or crown. ◆ About operating temperature and humidity Use within the range of operating temperature and humidity stated in the instruction manual. Do not use it in a place where the ambient temperature becomes higher than the operation temperature of the product or in a narrow closed place.
Page 5
F-RA-001-5R0 CAUTION ◆ Install horizontally. Do not install the product in the reverse direction and the lateral direction. Internal heat dissipation becomes insufficient, parts deteriorate, there is a risk of smoke and fire. ◆ Do not install in the place where cool air blows directly. There is a danger of condensation, leakage current and burnout.
CONTENTS ⅰ For Safe Use 1 Introduction 1-1 Introduction 1-2 Unpacking the POWER SUPPLY 1-3 Installation conditions 1-4 Points to be careful about in handling 1-5 Troubleshooting 2 Exterior view diagram 3 Operation manual 3-1 Outline 3-2 Operation method 4 Standard functions 4-1 Power supply for preamplifier 4-2 Over current protection 4-3 Over Voltage Protection...
1 Introduction 1 Introduction 1-1 Introduction Thank you very much for your purchase of our product, HIGH VOLTAGE POWER SUPPLY. We have done our best for the quality control of our products. Please handle this unit properly according to this instruction manual so that you can use the full performance of this unit safely for long.
1 Introduction 1-4 Points to be careful about in handling ・ For your safety connect the ground terminal of the chassis to EARTH securely ・ Use thicker (5SQ or thicker) and short wire for chassis grounding or load grounding, and ground at one point of the ground.
2 Exterior view diagram 2 Exterior view diagram Front panel ① ③ ② ④ ⑤ ⑥ ⑦ ⑧ ① POWER ON/OFF switch ⑤ Mode selector switch (option) ② HV ON/OFF switch ⑥ Left cursor key ③ Display ⑦ Right cursor key ④...
3 Operation manual 3-1 Outline EP series is high performance high voltage power supply for PMT application. Ultra compact size of just 8.35-inch(212mm) width integrated HV power supply and power supply for preamplifier ±15V and ±5V. The ultra low ripple noise is suitable for PMT and various other applications.
4 Standard functions 4 Standard functions 4-1 Power supply for preamplifier This unit outputs ±5V 500mA and ±15V 200mA. Output connector for preamplifier power supply Push the line inside while pressing this part with screwdriver. After taking the screwdriver away, make sure that the line does not come off by pulling it.
5. Option 5. Option 5-1. External Appearance CO - Optical cable connector (OUT) CO - Optical cable connector (IN) Master control device setting switch 5-2 connection diagram MATSUSADA CO - Optical cable POWER CO Series etc.
Set the switch 8 to the OFF side when the device connected to the optic fiber cable connection connector IN is a Matsusada Precision CO-G32, CO-RG, CO-HV, CO-U32, CO-E32 digital controller or a power supply with -LGob option.
5. Option 5-5 Command Syntax For example, the following programming sets the output voltage of the power supply connected UNIT1 to 1000V: ○○ VSET 1000 ① delimiter ② parameter ③ command ④ UNIT No. ① Enter a delimiter. ・RS-232C/RS-485 connection CR(0D ・LAN connection CR(0D...
5. Option 5-7 Character set for commands ・Do not use the characters (codes) in the shaded cells of the following ASCII code table. ・Use LF (0A ) and CR (0D ) only for delimiter. ・Command characters are not case sensitive. ・...
5. Option 5-9 Command List Category Command Features Page Output Voltage VSET Output voltage setting Output Setting of the output ON/OFF. Setting Remote setting Local/Remote Local setting Voltage VGET Output voltage measurement Output Measure Current IGET Output current measurement ment Status Checking Status Checking 5-10 Detail of command...
Page 17
5. Option REN Command Enable remote control. Format examples Initial value ・ When this command is received, all commands can be used. ・ When this command is received, “RE” is displayed on the screen. Remarks This command supports multi-command execution. GTL Command Disable remote control.
Page 18
5. Option STS Command Return the status of the power supply. Format examples Return # (UNIT number) (Status) ⇒UNIT1 is output ON、local operaton #1 CO LO Return #1 CF RM OVP ⇒UNIT1 is output status, remote control possible, CV operations examples status.