Routine Maintenance _____________________

A schedule should be established for the periodic inspection,
cleaning, and lint removal. The frequency of cleaning can best
be determined from experience at each location. Ideal drying
performance depends on sufficient airflow. Lint accumulation
can restrict airflow and is also a fire hazard.
Avoid using harsh chemicals when cleaning the dryer.
Suggested Cleaning Schedule
(Based on approximately 6-8 hours of daily operation)
To avoid electric shock and contacting
moving parts, discontinue electrical
supply any time a panel (without an
interlock switch) or guard is removed.
Every Three or Four Loads
Clean the lint screen - located behind the lint door (lower front
panel). Replace the lint screen if it is torn or damaged.
Weekly
Clean lint accumulation from the lint chamber, thermostat and
operating temperature sensor (located just below the drum).
Steam dryers: carefully clean steam coil fins (which are easily
damaged). We suggest using a vacuum cleaner with brush
attachment. Straighten bent fins with a fin comb.
90 Days
Clean any lint accumulation in and around the dryer.
Particular attention must be given to the removal of lint from
the burner area (located behind the upper front panel - control
door) and the area near the drive and fan motors.
Caution: Avoid touching the igniter and flame-sensor probes.
6 Months
Remove lint accumulation in the fresh-air intake openings and
in the exhaust ductwork.
Remove lint that may interfere with any back-draft damper
Check all back-draft dampers for proper operation.

Service / Parts Information ______________

Service must be performed by a qualified technician. If service
is required, contact the reseller who sold you the equipment. If
the reseller cannot be reached then contact our Service
Department for a reseller in your area.
Replacement parts can be obtained from your reseller or the
ADC factory. When ordering replacement parts from the factory,
you can FAX your order to ADC at +1 (508) 678-9447 or
telephone our Parts Department at +1 (508) 678-9000. Please
be prepared to provide the dryer model number, serial number,
description of the part, and the part number (if known).
This dryer is equipped with two manually resettable high-limit
thermostats. The burner high-limit is located in the top center
of the dryer behind the control door (upper front panel). The
exhaust high-limit is located in the duct above the lint trap (and
below the drum).
The wiring diagram for the dryer is located behind the control
panel.
113576 -1

Data Label Information ___________________

When contacting ADC, certain information is required to ensure
proper service/parts information from ADC. This information is
on the data label affixed to the right side panel area at the rear
of the dryer. When contacting ADC, please have the model
number and serial number available.
1. MODEL – Dryer model number.
2. SERIAL NUMBER – Unique identification number.
3. GAS TYPE – Gas type the dryer is constructed for.
4. HEAT INPUT – Rate of combustion.
5. ORIFICE SIZE – Injector opening (in mm).
6. ELECTRIC SERVICE – Electric supply type.
7. GAS PRESSURE – Supply and regulated pressure.
CE Rating Plate
AGA Rating Plate