Eterna LPIR1030G Safety And Installation Instructions

Eterna LPIR1030G Safety And Installation Instructions

10w led floodlight with120 pir

Advertisement

Quick Links

LAMP REPLACEMENT:
This luminaire has a LED lamp and is maintenance free, no lamp replacement is required.
SPECIFICATION:
• Detection range: Max. 7 metres at approx.120° scan (see notes above)
• Duration time non-adjustable 6 minutes
• Detection circuitry: Passive Infra-Red (PIR)
• Weatherproof: IP65
• Power required: AC 100 - 240V ~ 50-60Hz
• Maximum load: 10W LED
• Recommended power supply cable: H05RN-F 3G 1.0mm
• Protection: Class I
• Tempered Glass: Front lens
EVENTUALLY, YOU MAY WANT TO REPLACE THIS LIGHT FITTING:
When your product comes to the end of its life or you choose to update or upgrade it by replacing
it, please do not dispose of it with your normal household waste and please recycle where facilities
exist. When you need to dispose of this fitting you can check with your retailer or local authority
for suitable options. New regulations require the recycling of Waste from Electrical and Electronic
Equipment (European "WEEE Directive" effective August 2005—UK WEEE Regulations effective 2nd
January 2007). Environment Agency Registered Producer: WEE/GA0248QZ.
IF YOU EXPERIENCE PROBLEMS:
If your product is defective or develops a fault, please return it to the place where you bought it.
You can call our helpline for advice. The helpline will gladly give advice on any aspect of any Eterna
Lighting product but may not be able to give specific instructions regarding individual installations.
If in doubt, consult a qualified electrician.
111230-SM
HELPLINE:
• T: 01933 673 144
• F: 01933 678 083
• E: sales@eterna-lighting.co.uk
2
Visit our website:
www.eterna-lighting.co.uk
SAFETY AND INSTALLATION INSTRUCTIONS
Pack contents:
Model:
1 x Floodlight
LPIR1030G
10W LED Floodlight With120° PIR
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE USING YOUR NEW FITTING
PLEASE RETAIN FOR FUTURE REFERENCE

Advertisement

loading
Need help?

Need help?

Do you have a question about the LPIR1030G and is the answer not in the manual?

Questions and answers

Summary of Contents for Eterna LPIR1030G

  • Page 1 If your product is defective or develops a fault, please return it to the place where you bought it. You can call our helpline for advice. The helpline will gladly give advice on any aspect of any Eterna Lighting product but may not be able to give specific instructions regarding individual installations.
  • Page 2 fitting is fit for the purpose for which you have centre of the area to be scanned and slowly towards sun. intended it. Eterna Lighting cannot accept any adjust the angle of the sensor arm vertically liability for loss, damage or premature failure ����...
  • Page 3 Troubleshooting And User Hints & Cleaning TROUBLESHOOTING AND USER HINTS: Note: all passive infra red detectors are more sensitive in cold and dry weather than warm and wet weather. PROBLEM POSSIBLE CAUSE SUGGESTED REMEDY Check all connections, and MCB Fuses / 1.