Configuration Overview

Further configuration is possible to allow personalisation of your SMS Lite. You can assign a site
name to the SMS Lite, as well as naming each of the inputs and outputs, and assigning phone(s) to
these. The SMS Lite can be configured with up to 4 phone numbers allowing multiple user
notifications and control options.
Tip – DO NOT use a space in the naming convention for the Site Name, Inputs or Outputs i.e. "Back Gate" should
read "BackGate". Or "High Lvl" should read "HighLvl". Remember to keep the names less than 8 characters long.
All configuration text messages sent to the SMS Lite must in the form of:
#[PIN][space]<object>:<item>=<value>[dot]
e.g.
#12345 Site:Name=Shed1.
Or
#12345 INP1:Name=Pump.
Configuration options are shown in the following table:
Object
Site
INP1, INP2, INP3, INP4
These are the 4 individually
configurable inputs
RLY1, RLY2
These are the 2 outputs which
allow you to turn on / off or
pulse
Ph1, Ph2, Ph3, Ph4
Phone numbers of people who
receive alarm escalations or
can control inputs
Configuration messages can be sent individually with one text message per configuration instruction
or in a combined text message:
SMS Lite 4G– User Guide
Item
Name
Name
Phones
Name
Phones
Number
© 2021 QTech Data Systems Ltd
Value
The name of the site where
the SMS Lite is installed. (8-
character limit)
An identifying name for the
input. (8-character limit)
Ph1→Ph4
Which configured phone
number(s) will receive
notifications from this input.
An identifying name for the
output. (8-character limit)
Ph1→Ph4
Which configured phone
number(s) have permission to
control this output.
Local or International format
(e.g. 021...or +6421....)
The phone number(s) that will
receive notifications and/or
have control. Up to 4 people.