(AL6) Filling solenoid valve and/or level sensor fault.
This may occur during the initial phase of the Turkish bath or
during the function. The cause may be a blocked sensor, an
obstructed filling solenoid valve or lack of water.
It may also occur during the final draining phase of the scale
removal cycle.
TOP model: he display shows AL6. The function (Turkish bath
or scale removal cycle) is interrupted.
AL6
TT model: the "alarm" and "Turkish bath" keys remain on (white
light) and the second LED from the top will flash. The function
(Turkish bath or scale removal cycle) will be interrupted.
(AL7) Temperature not reached in the shower unit.
This may occur during the Turkish bath, due to a faulty heating
element. Or, if the initial temperature is lower than 25 °C and
the function is active for 5 minutes, the probe does not measure
a temperature increase of at least 5 °C (e.g. the shower unit door
is open).
TOP model only: the display shows AL7 for a few seconds and
the function ends normally.
AL7
(AL13) Activation of the safety thermostat.
This may occur during the Turkish bath.
TOP model: the display will show AL13 for a few seconds and
it will not be possible to start the function; if instead the alarm
appears when the function is in progress, it will be interrupted .
AL13
TT model: the "alarm" key remains on (white light) and the
"Turkish bath" key will flash; it will not be possible to start the
function. If instead the alarm appears when the function is in
progress, it will be interrupted.
(AL14) Error accessing the card where the audio files are
stored.
This may occur when playing, copying or deleting an audio
file.
TOP model only: the display will show AL14 for a few seconds
and it will not be possible to use the MP3 player .
If instead the alarm appears when the function is in progress, it
will be interrupted.
AL14
(AL15) Radio malfunction.
This may occur due to failed communication between the
control panel and the system.
TOP model only: the display will show AL15 for a few seconds
and it will not be possible to use the radio.
If instead the alarm appears when the function is in progress, it
will be interrupted.
AL15