(2). Improper screwing of the screws may cause the troubles shown in Fig.35.
(3). If gap still exists between ceiling and decoration panel after tightening the screws, readjust
the height of the indoor unit. (Fig.36)
(4). Wire the swing flap motor as shown in Fig.37.
4.6.2 Installing the Panel
(1). Place the panel at the unit, and latch the hooks beside and opposite the swing flap motor.
(2). Latch other two hooks.
(3). Tighten four hexagonal screws under the latches about 15mm.