loading

Summary of Contents for Sharp GS-XP9FGR

  • Page 1 GS-XP9FGR FLOOR STANDING TYPE ROOM AIR CONDITIONER GS-XP12FGR OPERATION MANUAL GS-XP18FGR GS-XPM9FGR AIRE ACONDICIONADO CONSUELA DE SUELO GS-XPM12FGR MANUAL DE INSTRUCCIONES GS-XPM18FGR CONDIZIONATORE D’ARIA A PAVIMENTO Air Conditioner MANUALE DI ISTRUZIONI AR CONDICIONADO DE CHÃO MANUAL DE OPERAÇÃO CLIMATISEUR SPLIT CONSOLE MURALE NOTICE D’UTILISATION...
  • Page 2 If the product is used for business purposes and you want to discard it: Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling.
  • Page 3: Table Of Contents

    ENGLISH Thank you for purchasing a SHARP air conditioner. Please read this manual carefully before operating the product. CONTENTS • IMPORTANT SAFETY INSTRUCTIONS ... E-1 • ONE-HOUR OFF TIMER ......E-12 • PART NAMES ..........E-3 • PLASMACLUSTER OPERATION....E-13 •...
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS CAUTIONS FOR USE Open a window or door periodically to ventilate the room, especially when using gas appliances. Insufficient ventilation may cause oxygen shortage. Do not operate the buttons with wet hand. It may cause electric shock. For safety, turn the circuit breaker off when not using the unit for an extended period of time.
  • Page 5: Part Names

    PART NAMES INDOOR UNIT 1 AIR OUTLET SELECTION Lamp (green) 2 AIR OUTLET SELECTION button 3 POWER. Button 4 Air Filters 5 Upper air outlet 6 Horizontal Adjustment Louvres 7 Vertical Adjustment Louvres 8 PLASMACLUSTER Lamp (blue) 9 OPERATION Lamp (red 0 TIMER Lamp (orange q RECEIVER Window w Inlet (Air)
  • Page 6 PART NAMES REMOTE CONTROL 1 TRANSMITTER 2 DISPLAY (Liquid Crystal Display) 3 PLASMACLUSTER Button 4 ON/OFF Button 5 THERMOSTAT Button 6 FULL POWER Button 7 MODE Button 8 ONE-HOUR OFF TIMER Button 9 TIMER ON Button (for setting the timer) 0 TIMER OFF Button (for setting the timer) q TIME ADVANCE Button w TIME REVERSE Button...
  • Page 7: Setting Deodorant Filters

    SETTING DEODORANT FILTERS The deodorant filters are packed as accessory of this unit. During operation of the air conditioner, the filters absorb odor elements from the air. air filter Open the front grille. mark Hold the two " " marked corners on the front grille and pull it toward yourself to open.
  • Page 8: Using The Remote Control

    USING THE REMOTE CONTROL LOADING BATTERIES Use two size-AAA (R03) batteries. Remove the remote control cover. Remote control cover Insert batteries in the compart- ment, making sure the ± and — polarities are correctly aligned. • The display indicates “AM 6:00”...
  • Page 9 CAUTION • Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light. • Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the signal.
  • Page 10: Basic Operation

    BASIC OPERATION Press the MODE button to select the op- eration mode. AUTO HEAT COOL Press the ON/OFF button to start opera- tion. • The red OPERATION lamp ( ) on the unit will light. Press the THERMOSTAT button to set the desired temperature.
  • Page 11 TIPS ABOUT AUTO MODE (GS-XP9FGR,GS-XP12FGR,GS-XP18FGR) In the AUTO mode, the temperature setting and mode are automatically se- lected according to the room temperature and outdoor temperature when the unit is turned on. Modes and Temperature Settings outdoor (¡C) temp. Cool...
  • Page 12: Adjusting The Air Flow Direction

    ADJUSTING THE AIR FLOW DIRECTION VERTICAL AIR FLOW DIRECTION Press the SWING button. MODE • The vertical adjustment louvre for upper outlet will change its angle continuously. Press the SWING button again when the vertical adjustment louvre for upper outlet SWING is at the desired position.
  • Page 13: Air Outlet Selection

    AIR OUTLET SELECTION Press AIR OUTLET SELECTION button, and choose " (Upper and lower automatic air outlets)" or " (Upper air outlet)". When setting air outlet to ". Air is blown out automatically from the upper and lower air outlet as shown below. MODE CONDITION AIR OUTLET...
  • Page 14: Full Power Operation

    FULL POWER OPERATION In this operation, the air conditioner works at maximum power to make the room cool or warm so rapidly that you can use it just after you come home. To activate the FULL POWER operation, press the FULL POWER button during operation.
  • Page 15: Plasmacluster Operation

    PLASMACLUSTER OPERATION The Plasmacluster ion generator inside the air conditioner will release positive and negative Plasmacluster ions into the room. Approximately the same numbers of positive and negative ions released into the air will reduce some airborne mold. During operation, press the PLASMACLUSTER button.
  • Page 16: Timer Operation

    TIMER OPERATION NOTE: Before setting the timer, make sure the clock is properly set with the current time. TIMER OFF Press the TIMER OFF ( ) button. The TIMER OFF indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the desired time.
  • Page 17 TIMER ON Press the TIMER ON ( ) button. The TIMER ON indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the de- sired time. (The time can be set in 10-minute increments.) Point the remote control at the signal receiver window on the unit and press the TIMER SET (SET/C) button.
  • Page 18: Main Unit Operation

    MAIN UNIT OPERATION Use this operation when the remote control is not available. TO TURN ON Press the POWER button on the unit. • The red OPERATION lamp ( ) on the unit will light and the unit will start operating in the AUTO mode.
  • Page 19 MAINTENANCE Be sure to stop the operation and turn off the circuit breaker before performing any maintenance. CLEANING THE UNIT AND THE REMOTE CONTROL Wipe them with a soft cloth. • Do not directly splash or pour water on them. We can cause electrical shock or equipment damage.
  • Page 20 MAINTENANCE CLEANING THE FILTERS The air filters should be cleaned every two weeks. OPEN THE FRONT GRILLE air filter Hold the two " " marked corners on the front mark grille and pull it toward yourself to open. REMOVE THE AIR FILTERS TAKE OFF THE DEODORANT FILTERS FROM THE AIR FILTERS CLEAN THE AIR FILTERS...
  • Page 21: Additional Notes On Operation

    ADDITIONAL NOTES ON OPERATION OPERATING TEMPERATURE RANGE INDOOR TEMP. OUTDOOR TEMP. 46°C (GS-XP9FGR,GS-XP12FGR,GS-XP18FGR) upper limit 32°C 43°C (GS-XPM9FGR,GS-XPM12FGR,GS-XPM18FGR) COOLING –10°C (GS-XP9FGR,GS-XP12FGR,GS-XP18FGR) lower limit 21°C 21°C (GS-XPM9FGR,GS-XPM12FGR,GS-XPM18FGR) upper limit 27°C 24°C HEATING lower limit – –15°C • The built-in protective device may prevent the unit from operating when used out of this range.
  • Page 22: Before Calling For Service

    BEFORE CALLING FOR SERVICE The following conditions do not denote equipment malfunctions UNIT DOES NOT OPERATE SWISHING NOISE The unit will not operate if it is turned on immediately The soft, swishing noise is the sound of the refrig- after it is turned off. The unit will not operate erant flowing inside the unit.
  • Page 23 If the unit appears to be malfunctioning, check the following points before calling for service. IF THE UNIT FAILS TO OPERATE Check to see if the circuit breaker has tripped or the fuse has blown. IF THE UNIT FAILS TO COOL (OR HEAT) THE ROOM EFFECTIVELY Check the outdoor unit to make Check the filters.
  • Page 24 SHARP ELECTRONICS (Europe) GmbH Sonninstra e 3, D-20097 Hamburg ß Printed in China TINSJA973JBRZ 06C-...

This manual is also suitable for:

Gs-xp12fgrGs-xp18fgrGs-xpm9fgrGs-xpm12fgrGs-xpm18fgr

Table of Contents