Alto-Shaam 500-TH-II/D Installation Operation & Maintenance page 8

Table of Contents

Advertisement

E L E C T R I C A L C O N N E C T I O N
The appliance must be installed by a qualified
service technician. The oven must be properly
grounded in accordance with the National
Electrical Code and applicable local codes.
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70.
electrical connections are to be made
in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is
easily accessible in case of an emergency. Arcing
will occur when connecting or disconnecting the
unit unless all controls are in the "
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
E L E C T R I C A L
VOLTAGE
PHASE
at 120
1
at 208
at 240
at 230
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
In Canada, all
" position.
OFF
/
kW
CYCLE
HZ
AMPS
60
16.0
1.95
60
12.5
2.2
60
12.5
3.0
50
12.0
2.75
#825/33/37
INSTALLATION
I N S T A L L A T I O N
All 208-240V 500-TH-II models will function
properly within a voltage range of 200 and 240.
750-TH-II and 1000-TH-II models at 208-240V
are dual rated units with a conversion switch
mounted under an access cover on the rear of the
oven, near the power cord.
With the voltage conversion switch in the
200-208V (UPPER) position, the oven will
function properly with a source voltage of
between 200 and 208.
With the voltage conversion switch in the
220-240V (LOWER) position, the unit will function
properly with a source voltage of between 220 and
240.
NOTE: ALL 208-240V units are shipped from the
factory with the voltage conversion switch
in the 220-240 position.
All 125V rated units will function properly with a
source voltage of between 100 and 125, 60 Hz.
The 125V rated units are provided with a cord and
plug [NEMA #5-20P]. Have a licensed electrician
install the proper outlet configuration as required
for the unit in accordance with applicable, local
electrical codes. This will assure a safe and
trouble-free installation.
Ensure that the voltage conversion switch position
and the available power source match.
VOLTAGE
PHASE
at 125
1
at 208
at 240
at 230
/
/
OPERATION
SERVICE MANUAL
/
kW
CYCLE
HZ
AMPS
60
16.8
2.1
60
14.4
3.0
60
14.4
2.6
50
10.4
2.4
. 7
PG