4.
Be sure to cycle the power OFF and ON after changing any values on a SCSI
controller, in a Setup program, or on a SCSI device. This ensures that the ne
initial values are loaded.
5.
Be sure that SCSI parity checking is consistently enabled or disabled on all
devices on the SCSI bus.
6.
Verify that the SCSI controllers and the SCSI devices are properly configured
and installed.
7.
Be sure that the SCSI bus is properly terminated.
8.
Be sure that, if necessary, the disk has a partition and is formatted.
Computer Hangs, or SCSI Controller Cannot Always Find the
Drives
1.
Check SCSI parity for consistency and be sure SCSI termination is set
correctly.
2.
Check cable length and integrity. Check pin-1 orientation.
3.
If the SCSI controller LED remains on when the computer hangs, the host
adapter may be interfering with your computer's operation. It may be installed
in a motherboard slot that does not support First-Party DMA (i.e., Bus
Master) data transfers.
105

Hide quick links:

Advertisement