Video settings page 2/2
Item
Setting
PROCESS
Select SETUP when you want to adjust the following items with the setup
CONTROL
menu, and PANEL when you want to adjust them with the submenus and the
lower control panel.
• Output video level
• Chroma output level
• Setup level (525/60 mode)
• Black level (625/50 mode)
• Chroma phase
• Y/C delay
• Sync/subcarrier phase
Y/C
When the "PROCESS CONTROL" is set to PANEL, set the Y/C delay value.
DELAY
PRESET: Fixed at factory default level.
VAR: Adjustable as desired.
To adjust
Press operation button F4 to indicate the VAR, press F4 again to highlight the
value, and then press the MARK/UP or LIST/DOWN button to change the value.
SYNC PH
When the "PROCESS CONTROL" is set to PANEL, adjust the sync phase by
pressing the MARK/UP or LIST/DOWN button.
SC PH
When the "PROCESS CONTROL" is set to PANEL, adjust the subcarrier
phase by pressing the MARK/UP or LIST/DOWN button. The SC-H value is
constant.
SG
Select the output of the internal audio or video signal generator for the source
signal.
OFF : Neither of the output of the internal audio nor video signal generator
AUDIO: The output of the internal audio signal generator
VIDEO : The output of the internal video signal generator
BOTH: Both of the output of the internal audio and video signal generators
AUD SG
Select the operation of the internal audio test signal generator.
SILNC : Silent signal.
1kHz : At 1 kHz, –20 dB FS sine wave is supplied to all audio input channels.
ID: Signal for recognizing each channel.
AUD SG
VID SG
SILNC
CB75
Y/C DLY
PROCESS
800
SYNC PH
CONTROL
PRESET
PANEL