5. Adjust the Data COMM cable slack from the console connector to the handlebar post
slider until snug and fully tighten the handlebar post cable cover fasteners (2x). Slide
extra slack into the handlebar post slider prior to tightening fasteners.
6. Reinstall the flywheel, see
on
page 85.
7. Hand rotate the pedals and verify that the Data COMM cable does NOT touch or rub
against the top of the flywheel.
If the cable rubs against the flywheel, the Data COMM cable slack must be
l
readjusted so that the cable does not touch the flywheel. This may require
removing the flywheel to make adjustments.
CAUTION: Make sure that the Data COMM cable does not rub against the top of
the flywheel. Readjust cable slack as necessary.
8. Ride the bike and verify that the console powers on and is operating normally.
Make sure the WATTS, RPM, TIME, DISTANCE, and INTERVAL metrics are
l
reporting correct information.
Access the service mode and review the ERROR LOG, see
l
page 156. Make sure there are no current logged error code 30s "Com-
munication issue with the LPCA".
9. Replace the front and rear belt guard covers, see
on page 47
10. Verify the bike operation, see
return to service.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
"Drive Belt, Generator Belt, and Flywheel Replacement"
"Operation Verification Checklist" on page 14
5 Replacement Procedures
Data COMM Cable Replacement
"Error Log" on
"Belt Guard Cover Replacement"
and
Page 83