a. Secure the Data COMM cable and Strain Gauge cables to the right fork weld-
ment upper push-mount cable tie at the following conditions:
Strain Gauge cable: Adjust the Strain Gauge cable so that there is a
l
small amount of slack from the left caliper cable clip across the frame to
the right side upper push-mount cable tie.
Data COMM cable: Pull the Data COMM cable upward thru the upper
l
fork weldment cable access hole until snug. Then secure the cable so
that the cable slack will NOT touch or rub against the top of the fly wheel.
When both cables are set to the install conditions, tighten the upper
l
push-pin cable tie.
3. Reinstall the Data COMM cable in the handlebar post:
a. Connect the previously installed cable puller exiting the bottom of the handle-
bar post to the Data COMM cable - console connector.
b. Lift the bottom of the handlebar assembly post next to the top of the handlebar
post frame weldment.
c. Grasp the cable puller and gently pull the Data COMM cable upward through
the handlebar post. Continue pulling the cable while inserting the handlebar
post into the handlebar post frame weldment. Be careful to not pinch or dam-
age the Data COMM cable while installing the handlebar post.
d. Use the handlebar height adjustment pop-pin to secure the handlebar post in
position.
e. Reinstall the handlebar post cable cover using the two 2.5 mm hex key bolts
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
5 Replacement Procedures
Data COMM Cable Replacement