Internal Transport Stream Serial Input; Ingresso Transport Stream Seriale Interno; Asi Serial Outputs; Uscite Asi Seriali - EuroTel ETL3100 Series Operating And Technical Manual

Table of Contents

Advertisement

Internal Transport Stream Serial Input

Internal Transport Stream Serial Input
Internal Transport Stream Serial Input
Internal Transport Stream Serial Input

Ingresso Transport Stream seriale interno

Ingresso Transport Stream seriale interno
Ingresso Transport Stream seriale interno
Ingresso Transport Stream seriale interno
•Also an internal serial Transport Stream input is provided.
•Viene gestito anche un ingresso interno Transport Stream seriale

ASI Serial Outputs

ASI Serial Outputs
ASI Serial Outputs
ASI Serial Outputs

Uscite ASI seriali

Uscite ASI seriali
Uscite ASI seriali
Uscite ASI seriali
•Two serial ASI transport stream outputs are provided. Each ASI output can be set to repeat ASI input A or ASI
input B Two serial ASI transport stream outputs are provided. Each ASI output can be set to repeat ASI
input A or ASI input B indifferently.
•Vengono fornite due uscite ASI seriali Transport Stream. Ogni uscita ASI può essere impostata per ripetere
indifferentemente l'ingresso ASI A o l'ingresso ASI B.

Transport Stream changeover

Transport Stream changeover
Transport Stream changeover
Transport Stream changeover

Scambio Transport Stream

Scambio Transport Stream
Scambio Transport Stream
Scambio Transport Stream
•The Modulator has a T T T T ransport S S S S tream (TS) changeover that works only in non-hierarchical mode.
Transport stream changeover provides two TS inputs, TS IN A and TS in B.
TS IN A can be associated to ASI input A or to the internal TS input; also TS IN B can be associated to ASI in B
or to the internal TS input.
TS changeover have five different operating modes:
1. TS Manual A: TS input is always TS IN A and the changeover is disabled.
2. TS Manual B: TS input is always TS IN B and the changeover is disabled.
3. TS Auto PrefA: if the changeover is enabled and no valid TS signal is detected on input A , it switches
automatically to input B. When both TS IN A and B are present, changeover selects TS IN A input.
4. TS Auto PrefB: if the changeover is enabled and no valid TS signal is detected on input B , it switches
automatically to input A. When both TS IN A and B are present, changeover selects TS IN B input.
5. TS AutoNoPref: if the changeover is enabled and no valid TS signal is detected on actual TS input, it
switches automatically to th other TS input.
When the TS changeover or hierarchical mode is enabled and TS input signal is absent from one of inputs,
Digital Input LED blinks.
When TS input signal is absent from both of inputs, Digital Input LED is off.
When TS input signal is present in both of inputs, Digital Input LED is on.
•Il modulatore ha uno scambio T T T T ransport S S S S tream (TS) che funziona solamente in modalità non-gerarchica.
Lo scambio TS fornisce due ingressi TS, TS IN A e TS IN B.
TS IN A può essere associato all'ingresso ASI A o all'ingresso TS interno; TS IN B può essere associato
all'ingresso ASI B o all'ingresso interno TS.
Lo scambio TS ha cinque diverse modalità di funzionamento:
1. TS Manual A: l'ingresso TS é sempre TS IN A e lo scambio é disabilitato.
Gen 2014
Rev. 009
CMAN3100
ETL3100
Page 27
27
27
27

Advertisement

Table of Contents
loading

Table of Contents