Resistance Table of Discharge Temperature Sensor for Outdoor (50K)
o
Temp(
C) Resistance(kΩ)
-29
853.5
-28
799.8
-27
750
-26
703.8
-25
660.8
-24
620.8
-23
580.6
-22
548.9
-21
516.6
-20
486.5
-19
458.3
-18
432
-17
407.4
-16
384.5
-15
362.9
-14
342.8
-13
323.9
-12
306.2
-11
289.6
-10
274
-9
259.3
-8
245.6
-7
232.6
-6
220.5
-5
209
-4
198.3
-3
199.1
-2
178.5
-1
169.5
0
161
1
153
2
145.4
3
138.3
4
131.5
5
125.1
6
119.1
7
113.4
8
108
9
102.8
90
o
Temp(
C)
Resistance(kΩ)
10
98
11
93.42
12
89.07
13
84.95
14
81.05
15
77.35
16
73.83
17
70.5
18
67.34
19
64.33
20
61.48
21
58.77
22
56.19
23
53.74
24
51.41
25
49.19
26
47.08
27
45.07
28
43.16
29
41.34
30
39.61
31
37.96
32
36.38
33
34.88
34
33.45
35
32.09
36
30.79
37
29.54
38
28.36
39
27.23
40
26.15
41
25.11
42
24.13
43
23.19
44
22.29
45
21.43
46
20.6
47
19.81
48
19.06
o
Temp(
C) Resistance(kΩ)
49
18.34
50
17.65
51
16.99
52
16.36
53
15.75
54
15.17
55
14.62
56
14.09
57
13.58
58
13.09
59
12.62
60
12.17
61
11.74
62
11.32
63
10.93
64
10.54
65
10.18
66
9.83
67
9.49
68
9.17
69
8.85
70
8.56
71
8.27
72
7.99
73
7.73
74
7.47
75
7.22
76
7.00
77
6.76
78
6.54
79
6.33
80
6.13
81
5.93
82
5.75
83
5.57
84
5.39
85
5.22
86
5.06
87
4.90
Service Manual
o
Temp(
C)
Resistance(kΩ)
88
4.75
89
4.61
90
4.47
91
4.33
92
4.20
93
4.08
94
3.96
95
3.84
96
3.73
97
3.62
98
3.51
99
3.41
100
3.32
101
3.22
102
3.13
103
3.04
104
2.96
105
2.87
106
2.79
107
2.72
108
2.64
109
2.57
110
2.50
111
2.43
112
2.37
113
2.30
114
2.24
115
2.18
116
2.12
117
2.07
118
2.02
119
1.96
120
1.91
121
1.86
122
1.82
123
1.77
124
1.73
125
1.68
126
1.64
Installation and Maintenance